Structural and constructional possibilities and restrictions in the renovation of historic timber-framed buildings: A case study of the church in Osiecznica
Beata Nowogońska, Joanna Drobiec, Rafał Markowski
Key points
From the paper's conclusion- These studies have indicated that a new method for determining the strength of wood in historic buildings needs to be developed.
Abstract
In buildings under conservation protection, all activities must comply with the rules established by the Law on the Protection and Care of Monuments. Conservation regulations impose numerous restrictions on altering historic building materials at every stage of construction projects, including damage diagnostics, design work, and restoration activities. In the case of historic frame buildings, repair solutions should not only adhere to technological and structural standards and construction laws but also preserve the architectural and structural integrity of the building. This article presents examples of how these two principals were applied in a church located in Osiecznica. In 2020, renovations were carried out on part of the church. The second phase of work is being planned and will involve the renovation of the southern and eastern walls, as well as the potential strengthening of the roof truss elements, depending on the results of diagnostic studies. These studies have indicated that a new method for determining the strength of wood in historic buildings needs to be developed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Partial and Asymmetric Strengthening of Timber Floors on the Seismic and Gravity-Load Response of Historic Unreinforced Masonry BuildingsBuildings · 2026
- Innovative Methods for Retrofitting Timber Structures for Seismic Safety: The Case of TekirdagBuildings · 2026
- COMPATIBLE ANCHORING SYSTEMS OF TEXTILE MEMBRANES IN ARCHITECTURAL HERITAGE: THE CASE STUDY OF COURTYARDS ROOFINGce/papers · 2026
- Soluções de escavação e contenção periférica com recalçamento de fachada de um edifício histórico em LisboaGeotecnia · 2026
- Comparative Seismic Performance of Hybrid Reinforced Concrete–Masonry Buildings Retrofitted with Different Strengthening Systems: A Nonlinear Finite Element StudyBuildings · 2026
- Seismic behavior degradation of timber frame considering joint looseness-induced tilt damage in multi-story historic timber structureStructures · 2026