Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine

Monitoring of 17O-water Dynamics in the Human Body Over One Week Using Direct 17O-MR Imaging: A Preliminary Study.

Moyoko Tomiyasu, Hiromi Sano, Yoshitaka Bito, Takashi Oono, Hiroyuki Kameda, Riwa Kishimoto, Tokuhiko Omatsu, Kohsuke Kudo,

Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine Baltimore, MD, USA. · Department of Molecular Imaging and Theranostics, National Institutes for Quantum Science and Technology Chiba, Chiba, Japan.

Key points

From the paper's conclusion
  • 17O-MRI visualized organ-specific water dynamics in vivo after H217O administration. The occipital lobe and liver showed time courses consistent with systemic tracer exchange, whereas the eye exhibited prolonged retention. Under the present protocol, 1H R2 mapping was not sufficiently sensitive.

Abstract

PURPOSE: Water is essential for physiological processes, yet tracking its in vivo dynamics remains challenging. This study used oxygen-17 (17O) MRI to monitor 17O signal changes in the occipital lobe after enriched H217O administration and to examine long-term 17O signal dynamics in the occipital lobe, eye, and liver. Additionally, proton MRI (1H-MRI) transverse relaxation rate (R2) changes were analyzed to assess H217O based on its negative-contrast effect. METHODS: A healthy adult received intravenous administration of enriched H217O (10 mol%, 2 mL/kg). Six MRI sessions were performed over 8 days using a clinical 3T scanner (Magnetom Prisma; Siemens Healthineers, Erlangen, Germany). During the initial dynamic 17O-MRI session, H217O was administered concurrently with occipital lobe imaging. Subsequent sessions evaluated longitudinal 17O-MRI changes in the occipital lobe, eye, and liver, together with 1H-MRI R2 mapping. Urine samples were collected after each session and analyzed by isotope ratio mass spectrometry to track H217O concentrations. RESULTS: In the occipital lobe, 17O signal began to increase about 30s after administration, peaked at 90s at more than 4 times baseline, and remained elevated at 1.4 times baseline on Day 8, closely paralleling urinary H217O. The liver showed a similar time course, whereas the eye showed prolonged retention followed by a marked decline between 48 and 96h. In contrast, 1H R2 values in the occipital lobe and liver showed minimal changes over time. Eye R2 data were unreliable because of motion-related artifacts. CONCLUSION: 17O-MRI visualized organ-specific water dynamics in vivo after H217O administration. The occipital lobe and liver showed time courses consistent with systemic tracer exchange, whereas the eye exhibited prolonged retention. Under the present protocol, 1H R2 mapping was not sufficiently sensitive.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Monitoring of 17O-water Dynamics in the Human Body Over One Week Using Direct 17O-MR Imaging: A Preliminary Study — Science Skim