Continuous Glucose Monitoring Metrics and Risks of Severe Hypoglycemia and Diabetic Ketoacidosis in Type 1 Diabetes: A Pooled Analysis.
Jiahuan Helen He, Natalie Daya Malek, Scott L Zeger, Justin B Echouffo-Tcheugui, Michael Fang, Elizabeth Selvin
Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD. · Department of Biostatistics, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD.
Key points
From the paper's conclusion- CGM hypoglycemic and glycemic variability metrics were associated with severe hypoglycemia risk independent of HbA1c, whereas TIR, mean glucose, and SD provided information for DKA risk beyond HbA1c. This supports the complementary value of CGM and HbA1c in risk assessment for severe hypoglycemia and DKA.
Abstract
OBJECTIVE: To investigate the link between continuous glucose monitoring (CGM) metrics and risk of severe hypoglycemia and diabetic ketoacidosis (DKA) in individuals of type 1 diabetes. RESEARCH DESIGN AND METHODS: We pooled individual-level data from 10 studies of type 1 diabetes. From a 14-day baseline period, we derived CGM metrics (time in range [TIR] 70-180 mg/dL, time above range [TAR], time below range [TBR], sensor mean glucose, SD, and percent coefficient of variation [%CV]) and CGM-defined hypo- and hyperglycemic episodes. We used Cox regression to evaluate associations with severe hypoglycemia and diabetic ketoacidosis, with and without adjustment for HbA1c. RESULTS: Among 1,550 participants, 65 severe hypoglycemia and 163 DKA events occurred over a median follow-up of 16 weeks. Higher TBR <70 and <54 mg/dL, SD, %CV, and CGM-defined hypoglycemic episodes were associated with greater risk of severe hypoglycemia independent of HbA1c (e.g., hazard ratio [HR] 1.52 [1.29-1.79] per 1-SD higher TBR <70). Lower TIR and higher mean glucose, SD, %CV, TAR, and hyperglycemic episodes were associated with higher DKA risk; these associations were attenuated after HbA1c adjustment, but TIR, sensor mean glucose, and SD remained statistically and clinically significant (e.g., HR 0.76, 95% CI 0.60-0.97 per 1-SD higher TIR). CONCLUSIONS: CGM hypoglycemic and glycemic variability metrics were associated with severe hypoglycemia risk independent of HbA1c, whereas TIR, mean glucose, and SD provided information for DKA risk beyond HbA1c. This supports the complementary value of CGM and HbA1c in risk assessment for severe hypoglycemia and DKA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Estimated glucose disposal rate is associated with continuous glucose monitoring metrics in type 1 diabetesScientific Reports · 2026
- Association of continuous glucose monitoring metrics with early diabetic kidney disease in early-onset type 2 diabetes.Frontiers in endocrinology · 2026
- Association of continuous glucose monitoring metrics with cardiovascular and kidney outcomes in type 2 diabetes: Data from the GRADE-CGM substudy.Journal of diabetes and its complications · 2026
- Exploratory Analysis of Continuous Glucose Monitoring Patterns in First-Degree Relatives with Dysglycemia at Risk of Progression to Stage 3 Type 1 Diabetes.Diabetes technology & therapeutics · 2026
- Association Between Short-Term Glycemic Variability Measured by Continuous Glucose Monitoring and Early Diabetic Kidney Disease in Type 2 Diabetes.Diabetes, metabolic syndrome and obesity : targets and therapy · 2026
- Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetesPLOS Digital Health · 2026