Advanced Hybrid Closed-Loop Insulin Delivery System in Asian Patients With Type 1 Diabetes: Exploratory Study.
Wanling Zeng, Authilakshmy N Manikam, Joan Khoo
Department of Endocrinology, Changi General Hospital, 2 Simei Street 3, Singapore, 529889, Singapore, 65 67888833.
Key points
From the paper's conclusion- Our study demonstrated the usability, safety, and possible improvement in glycemic outcomes with the MiniMed 780G system in Asian adults with T1D, independent of their baseline insulin therapies.
Abstract
BACKGROUND: The MiniMed 780G insulin delivery system has demonstrated improved hemoglobin A1c (HbA1c), time in range, and quality of life (QoL) in clinical trials, but real-world studies are lacking in Southeast Asia. OBJECTIVE: Our study aimed to explore the preliminary efficacy and safety of the Medtronic MiniMed 780G advanced hybrid closed-loop system, as well as the impact on QoL, in Southeast Asian adults with type 1 diabetes (T1D) who were previously on either multiple daily injections or conventional pump therapy over 24 weeks. METHODS: A prospective, single-center pilot study was conducted in patients with T1D on multiple daily injections or conventional pump therapy. Primary end points included the change in HbA1c at 12 and 24 weeks. Secondary end points included continuous glucose monitoring glycemic metrics, change in total daily insulin dose, QoL scores, and adverse events. RESULTS: Nine patients (n=5 male) with a mean age of 35 (SD 10.9) years completed the study. Mean HbA1c improved from 7.3% (SD 0.9%; mean 56.3, SD 9.8 mmol/mol) to 6.9% (SD 0.6%; mean 51.2, SD 6.4 mmol/mol) at 12 weeks and 7.0% (SD 0.6%; mean 53.0, SD 6.1 mmol/mol) at 24 weeks, respectively. All patients achieved the target time in the target range of over 70%, time above the target range of less than 25%, and time below the target range of less than 4% at 12 and 24 weeks. Reduction in total daily dose of insulin was observed for all patients at 24 weeks. CONCLUSIONS: Our study demonstrated the usability, safety, and possible improvement in glycemic outcomes with the MiniMed 780G system in Asian adults with T1D, independent of their baseline insulin therapies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improvement in Tight Glycemic Control in Adults with Type 1 Diabetes Using the MiniMed™ 780G Hybrid Closed-Loop System: A Real-World Evaluation.Current diabetes reviews · 2026
- Real-World MiniMed™ 780G Advanced Hybrid Closed-Loop Performance Across the Asia-Pacific Region.Diabetes technology & therapeutics · 2026
- Sustained Glycemic Outcomes with the MiniMed™ 780G System: Real-World Evidence from >16,000 Users Across 18 Latin American Countries Over Two Years.Diabetes technology & therapeutics · 2026
- Two-Year Real-Life Achievements of MiniMed 780G Advanced Closed-Loop System in Youth with Type 1 Diabetes: AWeSoMe Study Group Multicenter Prospective Extended Follow-Up.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026
- Long-Term Cost-Effectiveness of an Advanced Hybrid Closed-Loop Automated Insulin Delivery System Versus Multiple Daily Insulin Injections Plus Continuous Glucose Monitoring in Adults with Type 1 Diabetes in Australia.Advances in therapy · 2026
- Prospective multicenter evaluation of glycemic and patient-reported outcomes following transition to a next-generation continuous glucose monitoring system in users of advanced hybrid closed-loop technologyTherapeutic Advances in Endocrinology and Metabolism · 2026