A Benchmarking Framework for Real-Time 3D Pose Estimation in Motor Rehabilitation: Development and Proof-of-Concept Study.
Emanuel Alexander Lorenz, Beatrix Vereijken, Kerstin Bach, Xiaomeng Su
Department of Computer Science, Faculty of Information Technology and Electrical Engineering, Norwegian University of Science and Technology, Sem Sælands vei 9, Trondheim, Trøndelag, 7034, Norway, +47 41353626. · Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Trøndelag, Norway.
Key points
From the paper's conclusion- This study establishes a technical foundation for the standardized evaluation of markerless tracking for clinical applications, like motor rehabilitation. The morphing model enables interdataset comparison, and the proposed framework facilitates domain-specific interpretation of HPE performance. While further validation on pathological populations is required, this work provides the necessary engineering foundation for future validation studies.
Abstract
BACKGROUND: Accurate motor assessment is crucial for diagnosing and monitoring neurological and musculoskeletal disorders. However, traditional manual and semiautomated methods can be subjective, time-consuming, or expensive. Real-time 3D human pose estimation (HPE) is emerging as a low-cost, noninvasive alternative. However, its clinical adoption is limited due to a lack of thorough, standardized evaluation of its accuracy and robustness in real-world clinical settings. OBJECTIVE: This study aims to introduce a technical pipeline for evaluating the applicability of real-time 3D HPE in simulated clinical rehabilitation settings. METHODS: The framework facilitates the evaluation of an HPE model's spatial and spatiotemporal accuracy, real-time capability, and robustness against simulated common setup errors and camera position variations, using a marker-based motion capture system as a gold-standard baseline. To address the technical challenge of interdataset comparison, the framework includes a morphing model that harmonizes differing joint definitions. RESULTS: Applying the framework to a popular, accessible real-time algorithm (MediaPipe) on 4 healthy participants (N=127,828 frames) showed that simulated underexposure and defocus blur had negligible effects (rank-biserial correlation [RBC] ≤0.02), whereas body segment occlusion (mean-per-joint angular error [MPJAE] increase of 1.5, SD 10 degrees; +24.3%) and insufficient multiocular calibration (MPJAE increase of 7.8, SD 14 degrees; +123.4%, RBC=0.95) significantly degraded tracking accuracy. The framework also showed significant sensitivity to nonfrontal camera placements, both side- and back-facing views (RBC 0.41-0.49 and bias up to 2.2 degrees/37.1%), relative to stable frontal placements (RBC ≤0.03). The skeleton morphing module reduced Procrustes-aligned mean per joint position error (PA-MPJPE) by 55.29 mm (N=79,423 frames, 57.2% reduction) and its SD by 24.69 mm (N=79,423 frames, 50.7%). CONCLUSIONS: This study establishes a technical foundation for the standardized evaluation of markerless tracking for clinical applications, like motor rehabilitation. The morphing model enables interdataset comparison, and the proposed framework facilitates domain-specific interpretation of HPE performance. While further validation on pathological populations is required, this work provides the necessary engineering foundation for future validation studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation and Error Characterization of a Multi-View 3D Markerless Motion Capture System for Human Kinematics.Sensors (Basel, Switzerland) · 2026
- Reliability and Validity of AI-Based Pose Estimation Algorithms for Assessing Lower-Limb Flexibility and Joint Range of Motion.Sensors (Basel, Switzerland) · 2026
- Validation of Single-Camera MediaPipe BlazePose for Knee Joint Angle Measurement Across Multiple Functional Tasks: Concurrent Validity, Interrater Reliability, and Exploratory Test-Retest Reliability Study.JMIR rehabilitation and assistive technologies · 2026
- Evaluation of a markerless motion capture to measure 3D joint kinematics during occupational lifting tasks using mobile devicesApplied Ergonomics · 2026
- Assessment of monocular human pose estimation models for clinical movement analysisScientific Reports · 2025