Interpretable Continuous Glucose Monitoring Patterns of Type 1 and Type 2 Diabetes Across Cohorts and Sensors: Development and External Validation Study.
Faris Raza, Zaid Vellani
Artificial Intelligence and Computational Drug Discovery and Development (AICD3), Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, 1700 Fourth St, San Francisco, US. · Department of Microbiology, Immunology and Molecular Genetics, University of California, Los Angeles, Los Angeles, US.
Key points
From the paper's conclusion- In primary external testing, an interpretable 47-feature elastic-net model discriminated diabetes categories better than mean-glucose and clinical-summary baselines, with day-to-day glucose variability as the leading signal; because diagnosis and cohort coincided, this result may be optimistic. T1D errors concentrated in 1 adult-onset cohort, and sensor substitution changed predictions depending on the training setting, so classifiers pooling manufacturers should also be checked with paired-sensor recordings.
Abstract
BACKGROUND: Distinguishing type 1 diabetes (T1D) from type 2 diabetes (T2D) guides treatment, but adult presentations overlap. Continuous glucose monitoring (CGM) captures day-to-day glucose patterns, but CGM studies differ in recruitment, treatment, and sensor manufacturer, complicating classifier evaluation. OBJECTIVE: We tested whether 7-day CGM features distinguish source-labeled T1D, T2D, and no diabetes in adults when entire datasets are held out, compared interpretable and neural models with simple baselines, and measured how sensor substitution changes predictions. METHODS: We trained models on 4 adult datasets (AI-READI, ShanghaiT2DM, T1DiabetesGranada, and T1DEXI) and tested them on 4 others (Glucotypes, ShanghaiT1DM, AZT1D, and CGMacros), with every T1D/T2D-by-Dexcom/Abbott combination in both partitions. A cap of 100 participants per dataset and diagnosis yielded 492 training and 107 test participants. Each 7-day window provided 47 CGM features; predictions were averaged within participant. We compared mean-glucose and clinical-summary (mean, standard deviation, coefficient of variation, and glucose zones) logistic regression with elastic net, boosted trees, and 4 neural networks. The primary end point was participant-level macro-averaged area under the receiver operating characteristic curve (AUROC) with bootstrap 95% CIs. In 29 CGMacros participants wearing Abbott FreeStyle Libre Pro and Dexcom G6 Pro sensors simultaneously, we substituted Dexcom for Libre input. RESULTS: Among the 107 test participants (37 with T1D, 18 with T2D, and 52 without diabetes), elastic net achieved a macro-AUROC of 0.943 (95% CI 0.914-0.969) and a T1D-versus-T2D AUROC of 0.935 (95% CI 0.869-0.980), exceeding mean-glucose and clinical-summary logistic regression (paired gains over the latter 0.046, 95% CI 0.015-0.079, and 0.105, 95% CI 0.017-0.212). Pooled mean glucose was similar (T1D-minus-T2D difference 5.28 mg/dL, 95% CI -1.24 to 11.40), whereas the mean of daily differences (MODD), the leading elastic-net feature, was higher in T1D (21.11 mg/dL, 95% CI 18.31-23.83). T1D sensitivity was 78.4% overall, 92% in AZT1D, and 50% in ShanghaiT1DM; T2D precision was 45.7%. No dataset contained both T1D and T2D; when the T1D-versus-T2D contrast came from the shared Shanghai registry and sensor, elastic-net AUROC was 0.82-0.86; the 47 features also separated 2 T1D Dexcom cohorts, T1DEXI and AZT1D (AUROC 0.998, 95% CI 0.994-1.000). Clinical-summary logistic regression led within Shanghai (0.907 vs 0.859) and in Abbott-only evaluation (0.976 vs 0.887). Substituting Dexcom for Libre input reduced primary elastic-net log loss by 0.389 (95% CI 0.140-0.673) but increased Abbott-only log loss by 0.567 (95% CI 0.257-0.923). CONCLUSIONS: In primary external testing, an interpretable 47-feature elastic-net model discriminated diabetes categories better than mean-glucose and clinical-summary baselines, with day-to-day glucose variability as the leading signal; because diagnosis and cohort coincided, this result may be optimistic. T1D errors concentrated in 1 adult-onset cohort, and sensor substitution changed predictions depending on the training setting, so classifiers pooling manufacturers should also be checked with paired-sensor recordings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Correcting Differences Between Dexcom G6 Pro and FreeStyle Libre Pro Glucose Readings: Retrospective Paired-Device Study.JMIR diabetes · 2026
- Predictive Modelling of 3-Month Glycemic Target Achievement in Type 2 Diabetes Mellitus Using Artificial Intelligence and Continuous Glucose Monitoring: A Retrospective Cohort Study.Diabetes, obesity & metabolism · 2026
- Distinct insulin sensitivity profiles revealed by clustering based on continuous glucose monitoring data in people living with type 1 diabetes.Frontiers in endocrinology · 2026
- Machine Learning Models for Glycemic Prediction in Type 1 and Type 2 Diabetes: Systematic Review and Meta-Analysis.Journal of medical Internet research · 2026
- Subtyping and Prediction of the Glucose Based on the Hybrid Modeling of Deep Learning and Dietary Stimulated Glucose Metabolism Dynamical Model.Bulletin of mathematical biology · 2026
- Continuous glucose monitoring using the FreeStyle Libre Pro iQ in presymptomatic type 1 diabetes.Diabetologia · 2026