科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Drug metabolism and bioanalysis2026-01-02

Validation of a Method for Quantifying Elexacaftor, Elexacaftor-M23, Tezacaftor, Tezacaftor-M1, and Ivacaftor by HPLC-PDA.

Adriana H Sassone, Andrea S Saulo, Mario Sakson, Alejo G Dominas, Claudio Castaños, Paulo Cáceres Guido

一句话结论 · In one sentence

The limit of quantification for each calibration curve was 0.1 μg/ml. Intra-day precision (coefficient of variation [CV%]) ranged from 3.8% to 7.2%, and inter-day precision from 8.6% to 16.3%, meeting standard acceptance criteria. Retention times were 2.83 min for Ele-M23, 3.2 min for Elexacaftor, 5.6 min for Tezacaftor, 7.9 min for Tez-M1, 12.8 min for Ivacaftor, and 16.6 min for Itraconazole.

原始摘要(英文原文)· Original abstract
INTRODUCTION/OBJECTIVE: Cystic fibrosis is a genetic disease primarily treated with pharmacological modulators of the cystic fibrosis transmembrane conductance regulator (CFTR) protein, such as Elexacaftor, Tezacaftor, and Ivacaftor. This study developed and validated a method using Ultra-Fast Liquid Chromatography with Photodiode Array Detection (UFLC/PAD) to simultaneously quantify these three drugs and two of their main pharmacologically active metabolites (Ele-M23, Tez-M1) in plasma. METHODS: A Shimadzu UFLC/PAD system was used with a Shim-pack VP-ODS column and an isocratic mobile phase (water:acetonitrile, 35:65). Itraconazole served as the internal standard for plasma calibration curves (0.1-10 μg/ml). Samples were processed by protein precipitation with methanol followed by centrifugation. Linearity, limit of quantification (LQ), precision, and accuracy were validated. RESULTS: The limit of quantification for each calibration curve was 0.1 μg/ml. Intra-day precision (coefficient of variation [CV%]) ranged from 3.8% to 7.2%, and inter-day precision from 8.6% to 16.3%, meeting standard acceptance criteria. Retention times were 2.83 min for Ele-M23, 3.2 min for Elexacaftor, 5.6 min for Tezacaftor, 7.9 min for Tez-M1, 12.8 min for Ivacaftor, and 16.6 min for Itraconazole. DISCUSSION/CONCLUSION: The method is fast, reproducible, and suitable for the simultaneous quantification of CFTR modulators and their main metabolites in plasma. It is applicable in clinical laboratories for the therapeutic monitoring and optimization of cystic fibrosis pharmacotherapy.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Validation of a Method for Quantifying Elexacaftor, Elexacaftor-M23, Tezacaftor, Tezacaftor-M1, and Ivacaftor by HPLC-PDA. — 科研速览 Science Skim