Morphological and Hemodynamic Characteristics of the Ophthalmic Artery in Patients with Internal Carotid Artery Stenosis.
Jiao Sun, Yan-Ling Wang, Jia-Lin Wang
Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.
Key points
From the paper's conclusion- Patients with ICAS had a smaller initial OA diameter and ICA-OA angle, with lower simulated OA velocity under standardized boundary conditions. Larger studies incorporating patient-specific flow measurements are needed to assess the clinical relevance of these findings.
Abstract
BACKGROUND: Internal Carotid Artery Stenosis (ICAS) is an important cause of ischemic cerebrovascular disease and can also compromise ocular perfusion through the Ophthalmic Artery (OA), the first major intracranial branch of the Internal Carotid Artery (ICA). However, little is known about changes in OA morphology and hemodynamics in patients with different degrees of ICAS. MATERIALS AND METHODS: This cross-sectional study included 30 patients with ICAS and 8 healthy controls. One ICA-OA pair per participant was assessed using CTA-based reconstruction and CFD with uniform inlet and outlet conditions. Analyses compared patients with controls and explored differences among ICAS severity subgroups. RESULTS: Patients with ICAS had a smaller initial OA diameter (1.44 ± 0.30 vs. 1.73 ± 0.30 mm; P = 0.022) and ICA-OA angle (86.21 ± 24.92° vs. 113.60 ± 28.05°; P = 0.011) than healthy controls. Under the prescribed CFD conditions, mean OA velocity was also lower in the ICAS group (0.151 ± 0.095 vs. 0.244 ± 0.130 m/s; P = 0.029). DISCUSSION: These unadjusted comparisons describe differences in OA geometry and simulated flow between patients with ICAS and healthy controls. They do not establish an independent or progressive effect of stenosis severity, and the CFD estimates should not be interpreted as patient-specific physiological measurements. CONCLUSION: Patients with ICAS had a smaller initial OA diameter and ICA-OA angle, with lower simulated OA velocity under standardized boundary conditions. Larger studies incorporating patient-specific flow measurements are needed to assess the clinical relevance of these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Willisian collateral and carotid stenosis during large vessel occlusion stroke: Observations from computed tomography angiography.Journal of cerebrovascular and endovascular neurosurgery · 2026
- Characteristics and correlation analysis of CDFI in contralateral healthy eye in patients with CRAO.International ophthalmology · 2026
- Hemodynamic and Geometrical Parameters Associated with Carotid Artery Stenosis: A Cross-Sectional Study Using 4D Flow MRI and CFD.Annals of biomedical engineering · 2026
- Assessment of Carotid Siphon Pulsatility Index via Transorbital Window, an Alternative for Intracranial Measurements.Brain sciences · 2026
- Innovative application of pressure gradient measurement in internal carotid stenosis in patients undergoing carotid artery stenting (NOTICE-CAS): study protocol for a randomized, assessor-blinded, parallel-group clinical trialTrials · 2026
- Computed tomography-based evaluation of optic canal orientation and its relationship to the internal carotid artery: implications for skull base surgery.Surgical and radiologic anatomy : SRA · 2026