Enhanced Sensitivity in Free Thyroxine Measurement Using Equilibrium Dialysis and LC-MS/MS Coupled with Offline Anion-Exchange Solid-Phase Extraction.
Julie A Ray, Kelly Doyle
ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT, USA.
Key points
From the paper's conclusion- Diagnosis and monitoring of thyroid disorders often require the measurement of free thyroxine (fT4) by equilibrium dialysis, which is considered the gold-standard method for separating free hormones from biological samples.
Abstract
INTRODUCTION: According to the free hormone hypothesis, only the unbound hormone fraction exerts biological effects. Diagnosis and monitoring of thyroid disorders often require the measurement of free thyroxine (fT4) by equilibrium dialysis, which is considered the gold-standard method for separating free hormones from biological samples. OBJECTIVES: Our objective was to reduce complexity and enhance the sensitivity of a liquid chromatography-tandem mass spectrometry method with online solid-phase extraction (SPE) for measuring fT4. METHODS: Serum aliquots of 200 µL were subjected to equilibrium dialysis. Post-dialysis, increases in analytical sensitivity and specificity were achieved using weak-anion-based SPE prior to liquid chromatographic separation with subsequent analyte detection by a high-sensitivity SCIEX Triple Quad™ 7500 mass spectrometer. RESULTS: Lower and upper limits of quantitation (LLOQ and ULOQ) were 0.1 and 10 ng/dL, respectively. Intra- and inter-day precision evaluated using four matrix-matched quality control samples (0.15, 2.09, 5.10, and 7.94 ng/dL) indicated <10% imprecision, showing excellent agreement with the previous validated method (slope = 1.022, r = 0.9927, bias = 4.01%, n = 123). Chromatograms exhibited a substantial improvement in the signal-to-noise ratio at the LLOQ. CONCLUSION: A complex liquid chromatographic separation with online trapping-column method was successfully transitioned to a simpler off-line SPE liquid chromatographic separation method. Incorporating SPE desalting and using the improved instrument sensitivity of the SCIEX Triple Quad™ 7500 mass spectrometer significantly improved the performance. A reduced injection volume allowed sample reanalysis, which is beneficial for pediatric samples. This method provides a superior analytical approach for clinical fT4 measurement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-179 Development and Evaluation of a Novel Candidate Reference Method for the Simultaneous Determination of Serum Free Thyroxine (FT4) and Free Triiodothyronine (FT3) Using Equilibrium Dialysis Combined with Isotope Dilution LC-MS/MSClinical Chemistry · 2026
- B-369 Ensuring Quality of Free Hormone Measurements Through Detection of Membrane Leakage in Equilibrium DialysisClinical Chemistry · 2026
- Comparison of the Sensitivity of Histopathological and Immunohistochemical Analyses With That of Serum Hormone Measurements for Early Detection of Antithyroid Effects in Rats Treated With Iodide Uptake Inhibitors.Journal of applied toxicology : JAT · 2026
- 42 Assay-Specific Variability and Algorithm Refinement for Thyroglobulin Monitoring in Differentiated Thyroid CancerAmerican Journal of Clinical Pathology · 2026
- Steady-State Fluorescence Evaluation of Apparent Levothyroxine-BSA Binding and Its Modulation by Ciprofloxacin, Alendronate, and Metal Ions.Luminescence : the journal of biological and chemical luminescence · 2026
- Validation and Clinical Evaluation of an LC-MS/MS Method for Serum Full-Length Parathyroid Hormone 1-84 with Application to Chronic Kidney Disease.ACS pharmacology & translational science · 2026