Fully biodegradable versus nitinol occluder devices for transcatheter patent foramen ovale closure: a systematic review.
Abdulbari Alsaeed, Ahmad R Al-Qudimat, Mohammed Qintar, Raed M Al-Zoubi, Rufaidah H Alameen, Osama Mohamad
Surgical Research Section, Department of Surgery, Hamad Medical Corporation, Doha, Qatar. · Department of Cardiology, Heart Hospital, Hamad Medical Corporation, Doha, Qatar.
Key points
From the paper's conclusion- Eligible studies were randomized or comparative observational studies of patients aged 16 years or older undergoing PFO closure with biodegradable or bioresorbable versus nitinol or metallic occluders.
Abstract
Background: The optimal device platform for transcatheter patent foramen ovale (PFO) closure remains uncertain. Permanent nitinol occluders are widely used, but concerns persist regarding long-term foreign-body exposure and device-related complications. Fully biodegradable occluders have been developed to provide temporary septal support during endothelialization before gradual resorption, with the intended benefit accruing only after the device has resorbed. Methods: We systematically searched Medline, PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and trial registries through 17 February 2026. Eligible studies were randomized or comparative observational studies of patients aged 16 years or older undergoing PFO closure with biodegradable or bioresorbable versus nitinol or metallic occluders. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using RoB 2 for randomized evidence and ROBINS-I for non-randomized evidence. Because of clinical and methodological heterogeneity, findings were synthesized narratively. Results: Three comparative studies were included-one randomized trial and two retrospective cohorts-comprising 481 analyzed participants. Procedural success was high with both device types. Residual shunt generally decreased over time, with no clear advantage for either platform. Serious adverse events, device thrombosis, embolization or detachment, and atrial arrhythmias were uncommon, though event counts were small. Two of the three studies were migraine-specific cohorts, and the randomized trial enrolled a mixed-indication population in which treatment-resistant migraine was the most common single indication; the available evidence therefore reflects device-platform performance predominantly in migraine populations. No study followed participants substantially beyond the expected biodegradation window. Conclusion: Current evidence suggests similar short- to mid-term performance of biodegradable and nitinol occluders, but certainty is low to very low, and no study yet assesses the post-resorption period in which any advantage of a biodegradable platform would be expected to emerge. Larger multicenter studies with standardized imaging, rhythm monitoring, and follow-up extending beyond biodegradation are needed. Because two of the three studies were migraine-specific and event counts were small, these findings should not be extrapolated to stroke-prevention populations, and the absence of observed between-device differences should not be interpreted as equivalence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bioresorbable vs Metallic Occluders for Transcatheter Atrial Septal Defect ClosureJAMA · 2025
- Fully biodegradable ventricular septal defect occluders: from biomaterials to clinical translation.Cardiovascular intervention and therapeutics · 2026
- Suture-Mediated PFO Closure with the NobleStitch EL System: A Systematic Review and Single-Arm Meta-AnalysisEuropean Heart Journal - Valvular and Structural Heart Disease · 2026
- Feasibility and short-term outcomes of transcatheter closure of moderate-to-large perimembranous ventricular septal defects in children using bioabsorbable occluders: a prospective case series.Frontiers in cardiovascular medicine · 2026
- Clinical Characteristics, Mechanisms, and Management of Gore Cardioform Device-Related Thrombosis: A Comprehensive Review.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Polymeric and metallic occluders for interventional therapy of cardiovascular diseases.Biomaterials · 2026