Sternal Closure Techniques Using Steel Wires and Predictors of Sternal Wound Complications: A Randomized Controlled Trial.
Mohamed A Mogahed, Mohamed M Abdelaal, Wael M Elfeky, Ahmed R Elghanam, Mohamed M Elesawy, Mohamed M Abdelalim
Kafr Elsheikh University Department of Cardiothoracic Surgery Faculty of Medicine Kafr El Sheikh Egypt Department of Cardiothoracic Surgery, Faculty of Medicine, Kafr Elsheikh University, Kafr El Sheikh, Egypt.
Key points
From the paper's conclusion- The three steel-wire closure techniques demonstrated comparable early postoperative stability and similar rates of sternal wound complications. Technique choice may be based on surgeon preference.
Abstract
INTRODUCTION: Median sternotomy is the gold standard for cardiac surgery but carries a significant risk of wound complications, including sternal dehiscence and wound infections. OBJECTIVE: This study aimed to compare the early efficacy and complication rates of three distinct steel-wire sternal closure techniques and identify potential risk factors of complications. METHODS: We conducted a randomized controlled study on patients undergoing cardiac surgery. Patients were randomly allocated into three groups of sternal closure techniques: simple interrupted (Group A), figure-of-eight (Group B), or a modified combined technique (Group C). Baseline characteristics, intraoperative parameters, postoperative recovery outcomes, and sternal wound complications including sternal dehiscence and superficial and deep wound infections were evaluated. Binomial logistic regression was performed to determine independent risk factors for complications. RESULTS: One hundred sixty-five adult cardiac patients were finally included in the study. All three intervention groups (n = 55) were well-matched regarding baseline characteristics and intraoperative parameters. The incidence of sternal dehiscence (6.1%) and superficial (7.9%) and deep wound infections (3.6%) did not differ significantly among the three wire closure techniques (P > 0.05). However, logistic regression identified numerous factors associated with superficial sternal wound infections including old age, obesity (body mass index > 30), comorbidities, elevated C-reactive protein and HbA1C, prolonged cardiopulmonary bypass time, extended operative time, and longer intensive care unit stay (P < 0.05 for all). CONCLUSION: The three steel-wire closure techniques demonstrated comparable early postoperative stability and similar rates of sternal wound complications. Technique choice may be based on surgeon preference.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rigid plate fixation versus wire cerclage for sternal closure after coronary artery bypass grafting: a retrospective cohort study.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026
- Risk factors and clinical implications of sternal dehiscence following clamshell incision in bilateral lung transplantation.Journal of thoracic disease · 2026
- From debridement to definitive closure: an experience-based staged approach to sternal wound infectionEuropean Journal of Plastic Surgery · 2026
- Diagnosis and management of post-sternotomy wound infections after cardiac surgery: an updated comprehensive reviewJournal of Cardiothoracic Surgery · 2026
- Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes.Plastic and reconstructive surgery. Global open · 2026
- Resection and Individualized Chest Wall Reconstruction for Sternal Osteochondroma Complicated by Superficial Postoperative Wound Infection: A Case Report.Annali italiani di chirurgia · 2026