Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes.
Jessica J Farzan, Anam J Furrukh, Andrew M Haggarty, Raymond M Dunn
From the Division of Plastic and Reconstructive Surgery, UMass Chan Medical School, Worcester, MA.
Key points
From the paper's conclusion- The disparate outcomes between continuous and releasable plating systems raise questions regarding the true rigidity of releasable sternal plates. We hypothesize that the emergency release mechanism could compromise the plate's construct rigidity, leading to micromotion that may promote infection and nonunion, whereas its added bulk may increase hardware removal rates. Balancing reentry capability with complication risks is crucial. Future research comparing the biomechanical properties of each system is necessary to elucidate these differences and optimize sternal fixation techniques.
Abstract
BACKGROUND: Median sternotomy involves a longitudinal sternal incision that disrupts the sternum's structural integrity and biomechanical properties crucial for cardiopulmonary function. Although sternal closure with wire cerclage suffices for most patients, some experience sternal nonunion, necessitating sternal rigid plate fixation. We compare outcomes of "continuous" plating systems (single-piece hardware) and "releasable" plating systems (2-piece hardware with an emergency release mechanism) for sternal closure. METHODS: In accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, 2 independent reviewers screened articles across 6 databases, using predefined criteria. Data extraction, focusing on study details, closure systems, sample sizes, and surgical outcomes, was performed in duplicate. The Fisher exact test was used for statistical analysis. RESULTS: The review analyzed 25 studies (1878 patients) for continuous and 17 studies (416 patients) for releasable plating systems. The latter demonstrated significantly higher rates of sternal nonunion, superficial and deep sternal wound infections, persistent pain, bleeding, hematomas, seromas, plate fractures, screw-related complications, and hardware removals (P < 0.05). Continuous plating systems demonstrated better outcomes overall. CONCLUSIONS: The disparate outcomes between continuous and releasable plating systems raise questions regarding the true rigidity of releasable sternal plates. We hypothesize that the emergency release mechanism could compromise the plate's construct rigidity, leading to micromotion that may promote infection and nonunion, whereas its added bulk may increase hardware removal rates. Balancing reentry capability with complication risks is crucial. Future research comparing the biomechanical properties of each system is necessary to elucidate these differences and optimize sternal fixation techniques.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rigid plate fixation versus wire cerclage for sternal closure after coronary artery bypass grafting: a retrospective cohort study.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026
- Exploring Collaborative Approaches: An Analysis of Plastic and Cardiothoracic Surgery Integration.Plastic and reconstructive surgery. Global open · 2026
- Sternal Closure Techniques Using Steel Wires and Predictors of Sternal Wound Complications: A Randomized Controlled Trial.Brazilian journal of cardiovascular surgery · 2026
- Two-hour ex vivo biomechanical evaluation of glass polyalkenoate cement-augmented sternal fixation in sheep.Clinical biomechanics (Bristol, Avon) · 2026
- Dynamic craniotomy: translational development, biomechanical validation, and early clinical experience of an adaptive cranial bone flap fixation platform.Neurosurgical focus · 2026
- Comparative risk of instrumentation failure in dynamic and rigid spinal stabilization: a propensity-matched cohort study.Neurosurgical review · 2026