Comparative Visual Outcomes and Complications of Light Adjustable Intraocular Lens Technology: A Scoping Review.
Anita B Chander, Eric Tam, Sohel Somani
Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada. · U Vision Group, Brampton, ON, Canada.
Key points
From the paper's conclusion- LAL technology is associated with reduced residual refractive cylinder and improved UCVA compared to monofocal IOLs. The small number of comparative studies and heterogeneity across sources limit the strength of this evidence. The potential for UV light contamination with first generation models and LDD treatment delays warrant consideration.
Abstract
PURPOSE: A scoping review was completed to evaluate visual outcomes of the light adjustable lens (LAL) relative to alternative intraocular lenses (IOLs) and post-operative adverse events associated with the LAL. METHODS: A structured search of MEDLINE, EMBASE, and CENTRAL was completed to identify primary studies of cataract surgery with LAL implantation. RESULTS: Twenty studies (1743 eyes) were included. Six studies (30%) compared the visual performance of LAL to another IOL, reporting sphere (n = 2 studies), spherical equivalent (SE; n = 5), and residual cylinder (n = 6). Residual cylinder was lower with the LAL across all 6 studies, whereas comparative SE outcomes were variable. Uncorrected visual acuity (UCVA) was reported in 4 studies, with all 4 studies demonstrating improved UCVA with the LAL. Adverse events were reported in 18 studies (90%). Posterior capsular opacification or YAG capsulotomy was reported in the largest number of studies (n = 8 studies), with study-level proportions ranging from 0.7% to 28.6% of eyes. Macular edema was reported in 6 studies (0.6% to 10.9% of eyes) and secondary surgical interventions in 5 studies (1.0% to 12.5% of eyes). The first light delivery device (LDD) treatment was performed 17 to 24 days after surgery in 7 studies (35%). CONCLUSION: LAL technology is associated with reduced residual refractive cylinder and improved UCVA compared to monofocal IOLs. The small number of comparative studies and heterogeneity across sources limit the strength of this evidence. The potential for UV light contamination with first generation models and LDD treatment delays warrant consideration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Central Optic Distortion and Internal Higher Order Aberrations From Ultraviolet-Mediated Polymer Migration in Light Adjustable Lenses.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Residual Astigmatism With Toric Versus Light-Adjustable Intraocular Lenses: A Power-Vector Model of the Effect of Alignment Uncertainty.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Optical Quality Degradation Following Nd:YAG Laser-Induced Intraocular Lens Pitting: A Multimodal Experimental Study.Vision (Basel, Switzerland) · 2026
- A One-Year Visual and Safety Evaluation of a Newly Available Trifocal Intraocular Lens in Patients With Bilateral Cataracts: Clinical Outcomes From a Prospective Study.Journal of ophthalmology · 2026
- Nd:YAG Capsulotomy Rates of Three FineVision Trifocal Intraocular Lens Platform Across Different Platforms: Results from a Multicenter Clinical Registry Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Comparison of Outcomes of Anterior Chamber Intraocular Lenses with Scleral-fixated Intraocular Lenses: A Systematic Review.Journal of ophthalmic & vision research · 2026