A Modified Needle Technique for Enlarging a Small Capsulorhexis Under the Main Incision.
Xin Liu, Jing Lu, Anpeng Pan, Lingying Ye, He Xie, Fang Yu, Xianhui Gong
Department of Cataract, Second Hospital of Jilin University, Changchun, People's Republic of China. · Department of Cataract, Eye Hospital of Wenzhou Medical University, Wenzhou, People's Republic of China.
Key points
From the paper's conclusion- The described 27‑gauge needle technique appears to be a feasible, safe, and accessible method for enlarging a small CCC in selected cases. It is particularly useful for managing small capsulorhexes situated under the main incision, where conventional instruments have limited access.
Abstract
PURPOSE: To describe and evaluate a modified technique for safely enlarging a small continuous curvilinear capsulorhexis (CCC) during cataract surgery, particularly when the margin of the small CCC lies beneath the main incision, where conventional capsule scissors are difficult or impossible to use. METHODS: We describe a bimanual technique in which a manually bent 27-gauge needle is used to create a controlled capsular flap while the capsulorhexis forceps simultaneously stabilize the anterior capsule, facilitating safe and controlled enlargement of a small primary CCC. The technique can be performed at various surgical stages after sufficient viscoelastic has been injected to flatten the anterior capsule. This procedure was applied in eyes requiring CCC enlargement. Clinical outcomes, including capsulorhexis diameters before and after enlargement (measured using image analysis software) and the occurrence of using complications (eg radial tears, zonular damage), were retrospectively analyzed. RESULTS: Between April and November 2025, a total of 1860 cataract surgeries were performed, of which 39 eyes (2.09%) required CCC enlargement. In 20 of these cases, the modified needle technique was employed, primarily for CCCs under the main incision. Enlargement was successful in all 20 cases, with the mean CCC diameter increasing from 4.34 ± 0.44 mm preoperatively to 5.07 ± 0.28 mm post-enlargement. No intraoperative complications such as radial capsular extension or zonular dialysis occurred. During follow-up, no late complications, such as capsular phimosis or intraocular lens decentration, were observed. CONCLUSION: The described 27‑gauge needle technique appears to be a feasible, safe, and accessible method for enlarging a small CCC in selected cases. It is particularly useful for managing small capsulorhexes situated under the main incision, where conventional instruments have limited access.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Button Nucleus Prolapse: A Safer Approach for Hard Nucleus in Manual Small Incision Cataract SurgeryTNOA Journal of Ophthalmic Science and Research · 2026
- Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.Cureus · 2026
- Capsule Retractor Extension Technique for Ectopia Lentis.Case reports in ophthalmological medicine · 2026
- Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropyleneJournal of Cataract & Refractive Surgery · 2025
- Horizontal Scleral Incisions for Fixation of Carlevale Intraocular Lens: A Useful Surgical VariantRetinal Cases & Brief Reports · 2026
- Scleral Cap Augmentation in Ocular Evisceration.Ophthalmic plastic and reconstructive surgery · 2026