XEN63 Gel Stent in Glaucoma: Narrative Review and Expert Perspectives on Patient Selection, Surgical Technique, and Perioperative Management.
Iqbal Ike K Ahmed, Jose Maria Martinez-De-La-Casa, Antonio Maria Fea, Karsten Klabe, Luis Abegão Pinto, Herbert A Reitsamer, Paramjit Singh, Ingeborg Stalmans,
John Moran Eye Center, University of Utah, Salt Lake City, UT, USA. · Department of Ophthalmology and ORL, Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San-Carlos (IdISSC), Universidad Complutense de Madrid, Facultad de Medicina, Madrid, Spain.
Key points
From the paper's conclusion- This narrative review summarizes the currently available evidence and expert surgical perspectives on patient selection, pre- and intraoperative practices, implantation technique, and postoperative practices with the 63 μm gel implant.
Abstract
The XEN gel stent (AbbVie Inc. North Chicago, IL, USA) is a minimally invasive bleb-forming surgical device designed to lower intraocular pressure (IOP). The 63 μm gel stent has a larger lumen than the 45 μm gel stent, creating lower outflow resistance, which may translate into greater IOP-lowering potential. However, the comparative evidence base remains limited, heterogeneous, and largely retrospective; the magnitude and durability of any advantage over the 45 μm device should be interpreted cautiously. This narrative review summarizes the currently available evidence and expert surgical perspectives on patient selection, pre- and intraoperative practices, implantation technique, and postoperative practices with the 63 μm gel implant. Particular attention is given to conjunctival and Tenon's tissue management, use of mitomycin C (MMC), management of postoperative IOP elevation, and recognition and treatment of hypotony. The article is based on a targeted review of the literature combined with unstructured expert input and was not conducted as a systematic review or formal Delphi consensus. Based on the available evidence and expert perspectives, the 63 μm gel stent may be a useful option for selected patients requiring IOP in the low- to mid-teens. However, outcomes depend heavily on patient factors, surgical technique, and postoperative care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficacy and safety of XEN63 gel implant with open conjunctiva technique.BMC ophthalmology · 2026
- XEN45 Gel Stent Versus PRESERFLO MicroShunt: Two-Year Real-World Outcomes from a Swiss Single Center.Journal of clinical medicine · 2026
- The efficacy and safety of the XEN63 glaucoma gel stent without Mitomycin C over the first 10 years.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Safety and Effectiveness of a Gel Stent in Refractory Glaucoma in China: Real-World Evidence at 12 Months.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Subconjunctival mitomycin C injection alters bleb survival and morphology but not intraocular pressure in a rabbit XEN63 model.Frontiers in medicine · 2026
- Matching of XEN®45 and PRESERFLO™ MicroShunt cases: Outcomes of a 3-year follow-upPLoS ONE · 2025