Matching of XEN®45 and PRESERFLO™ MicroShunt cases: Outcomes of a 3-year follow-up
Cemre Altas, Marcus Walckling, Tobias Brockmann, Fabian Stelzle, Anselm G. Jünemann, Thomas A. Fuchsluger
University of Rostock · Ernst Abbe University of Applied Sciences Jena
Key points
From the paper's conclusion- To compare long-term outcomes of XEN®45 (XEN) and PRESERFLO™ MicroShunt (PRESERFLO) implants in the surgical management of glaucoma over a 3-year follow-up period, focusing on intraocular pressure (IOP) reduction, need of medication, surgical success, and postoperative complications.
Abstract
OBJECTIVE: To compare long-term outcomes of XEN®45 (XEN) and PRESERFLO™ MicroShunt (PRESERFLO) implants in the surgical management of glaucoma over a 3-year follow-up period, focusing on intraocular pressure (IOP) reduction, need of medication, surgical success, and postoperative complications. METHODS: A retrospective, matched case control study was conducted, including 42 eyes with preceded implantation of a XEN or PRESERFLO. Patients were statistically matched using SPSS algorithms for glaucoma diagnosis, previous surgery, and demographics. Standardized success criteria defined surgical outcomes: complete success (IOP ≤ 15 mmHg or ≤ 18 mmHg without medications) and qualified success (IOP ≤ 15 mmHg with < 3 medications). Postoperative care and needling or revision interventions were recorded. Statistical analyzes included Wilcoxon, Mann-Whitney U, and t-tests. RESULTS: Both devices significantly reduced IOP and glaucoma medication over 3 years. XEN reduced IOP from 22.1 ± 8.6 mmHg to 13.5 ± 3.8 mmHg, while PRESERFLO reduced IOP from 22.1 ± 6.6 mmHg to 12.6 ± 4.0 mmHg (p > 0.05 for between-groups, 3 years postoperative). Medication use decreased from 2.4 ± 1.0 to 0.9 ± 1.4 for XEN and 3.1 ± 1.1 to 1.1 ± 0.9 for PRESERFLO (p > 0.05 for between-groups). Surgical success rates were similar after 3 years. PRESERFLO showed fewer postoperative revisions (28.6% vs. 42.9% for XEN; p > 0.05). Early hypotony occurred more frequently with XEN (17 vs. 7 cases; p = 0.029). CONCLUSION: Both XEN and PRESERFLO effectively reduce IOP and the need for glaucoma medication, with comparable surgical success rates after 3 years. PRESERFLO demonstrated a lower revision rate and reduced frequency of early postoperative hypotony. These findings support both implants as viable options for minimally invasive glaucoma surgery, with low risk profiles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- XEN45 Gel Stent Versus PRESERFLO MicroShunt: Two-Year Real-World Outcomes from a Swiss Single Center.Journal of clinical medicine · 2026
- Comparison of one-year postoperative outcomes between PreserFlo MicroShunt and trabeculectomy in Japanese patients with open angle glaucoma: a retrospective cohort study using propensity score matchingJapanese Journal of Ophthalmology · 2026
- Comparative outcomes of PreserFloTMMicroShunt in primary open-angle and pseudoexfoliative glaucoma: A matched analysis.PloS one · 2026
- Comparison of Early Outcomes of PreserFlo MicroShunt, Ex-PRESS, and Trabeculectomy in Primary Open-angle Glaucoma.Journal of glaucoma · 2026
- Two-year outcomes of PRESERFLO MicroShunt implantation in a real-world heterogeneous glaucoma cohort: a retrospective single-center study.Frontiers in ophthalmology · 2026
- PreserFlo MicroShunt Outcomes in Asia: Two-Year Results with Exploratory Comparisons of Standalone and Combined Surgery from a Regional Tertiary Centre.Journal of clinical medicine · 2026