Diagnostic Accuracy of Tidal Breathing Patterns in Assessing Airflow Obstruction Compared with Spirometry.
Britt J M H Dörssers, Anouk W Vaes, Rob Hagmeijer, Manon H J M Broekhuijsen-Godding, Frits M E Franssen, Dennis S van Putten, Martijn A Spruit, Sami O Simons
Department of Research and Development, Ciro, Horn, The Netherlands. · Engineering Fluid Dynamics, University of Twente, Enschede, The Netherlands.
Key points
From the paper's conclusion- Nasal pressure analysis showed moderate performance in detecting spirometry-defined airway obstruction, suggesting limited potential as a non-invasive tool. Further research is needed to establish its possible clinical utility.
Abstract
PURPOSE: Spirometry is the standard for assessing airflow obstruction in COPD, but low-burden screening tools may support primary care in identifying patients needing referral, potentially enabling earlier diagnosis and timely disease management. A novel, easy-to-use device (AMES BV, the Netherlands) estimates obstruction from nasal pressure variation during tidal breathing and may support referral decisions. This study aimed to assess the ability of nasal pressure analysis to identify airflow obstruction compared with spirometry. PATIENTS AND METHODS: Cross-sectional study at a hospital pulmonary function laboratory. In a convenience sample of participants referred for routine spirometry, nasal pressure variation was measured via a nasal cannula and converted into an obstruction index, expressed as an estimated Forced Expiratory Volume in the first second/Forced Vital Capacity ratio (FEV1/FVC). The ability to identify spirometry-derived obstruction (FEV1/FVC<0.70) was assessed by sensitivity, specificity, and accuracy, with spirometry as reference standard. Bland-Altman plots were used to assess agreement between the estimated FEV1/FVC ratio (derived from nasal pressure variation) and spirometry-defined FEV1/FVC ratio. RESULTS: Both procedures were performed in 192 participants (median age 66 (IQR 56-74) yrs; 39% male). Nasal pressure analysis showed moderate performance in detecting obstruction (sensitivity 66%, specificity 63%, accuracy 64%). The Bland-Altman plot showed variability between both measurements, consistent with moderate classification performance, with a mean difference of -0.016 and 95% limits of agreement ranging from -0.43 to 0.40. CONCLUSION: Nasal pressure analysis showed moderate performance in detecting spirometry-defined airway obstruction, suggesting limited potential as a non-invasive tool. Further research is needed to establish its possible clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement and Repeatability of Three Fractional Exhaled Nitric Oxide Analyzers in Patients with Chronic Obstructive Pulmonary Disease: A Prospective Comparative Study.Journal of clinical medicine · 2026
- Comparative evaluation of impulse oscillometry and spirometry for the detection of small airway disease in patients with obstructive airway diseases.Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace · 2026
- The impact of peak expiratory flow variability on FEV1 repeatabilityDiscover Respiratory Health · 2026
- Bedside Spirometry, Dyspnea Severity and Inflammatory Markers for Predicting Noninvasive Ventilation Requirement in Acute Exacerbation of Chronic Obstructive Pulmonary Disease.Medical principles and practice : international journal of the Kuwait University, Health Science Centre · 2026
- Exploratory Analysis of Electrical Impedance Tomography Features Associated with Spirometric Airflow Limitation.Computational and structural biotechnology journal · 2026
- Multiscale Entropy Reveals Reduced Airflow Complexity in Chronic Obstructive Pulmonary Disease: Associations with Spirometry and Diagnostic Utility.Annals of biomedical engineering · 2026