Pulse Physiology Engine to simulate transient oxygen changes and closed-loop, autonomous pump control during venovenous extracorporeal membrane oxygenation.
Rei Ukita, Sriya Bapatla, Jeffrey Webb, Aaron Bray, Yerin Woo, Andrew R Kumpfbeck, Steven P Keller, Rachel B Clipp
Key points
From the paper's conclusion- This work (1) compares transient venous oxygen saturation (SvO 2 ) simulations in Pulse to in vivo pig data, (2) implements pump speed as a model input, and (3) simulates closed-loop pump control using proportional integral (PI) controller.
Abstract
Venovenous extracorporeal membrane oxygenation (VV-ECMO) is a lifesaving respiratory support therapy growing in clinical volume worldwide. Its physiology is complex, yet management strategies vary widely across centers. Meanwhile, patient-to-patient variability makes standardization difficult. To address these challenges, we previously presented a patient-specific model of VV-ECMO based on the Pulse Physiology Engine (Pulse). However, previous study's scope was limited to validating steady-state physiology. This work (1) compares transient venous oxygen saturation (SvO 2 ) simulations in Pulse to in vivo pig data, (2) implements pump speed as a model input, and (3) simulates closed-loop pump control using proportional integral (PI) controller. The time constants from SvO 2 simulations show significant, positive correlations with in vivo data (coefficient=0.929, p<0.001). Furthermore, both experimental and simulated time constants show significant, negative correlation with their corresponding blood flow (p<0.05). With pump speed as model input, the model predicts achieved blood flow rate in two different clinical systems with reasonable accuracy. Finally, a well-tuned PI pump controller can reject disturbances induced by the ventilator, while there should be precautions for setpoint SvO 2 change and oxygenator thrombosis. Future work will validate the closed-loop findings in a large animal model to bring Pulse closer towards a digital-twin model of VV-ECMO patients. Clinical Trial Registration not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-specific, computational model of venovenous extracorporeal membrane oxygenation based on pulse physiology engine.Scientific reports · 2026
- A multimodal strategy for assessing oxygenator degradation during extracorporeal membrane oxygenation (ECMO): an in vitro evaluationat - Automatisierungstechnik · 2026
- Hemodynamic effects of a novel counter-pulsatile system for extracorporeal membrane oxygenation.Perfusion · 2026
- Automated Blood Conditioning for Artificial Lung Evaluation: A Feasibility Study.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Impact of Pulsatile Flow on Pulmonary Transvascular Fluid Flux During Veno-Pulmonary Arterial ECMO: A Pilot Ovine Study.Shock (Augusta, Ga.) · 2026
- The Early Assessment of a Newly Developed Maglev Extracorporeal Mechanical Oxygenation System: 14 Day In Vivo Study Report.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026