Respiratory motion-corrected quiescent period gating magnetic resonance attenuation correction (Q.MRAC) for enhancing quantitative accuracy in hepatic [18F]FDG PET/MRI: a dual-domain motion compensation study.
Hua Lin, Yu-Mei Pu, Li Li, Ming-Gang Su, Chun-Chao Xia
Department of Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, China. · Department of Radiology, West China Second Hospital of Sichuan University, Chengdu, China.
Key points
From the paper's conclusion- Dual-domain motion correction (Q.Static + Q.MRAC) significantly improves SUV quantification accuracy in the upper lobe of right liver. These findings establish a foundation for achieving greater accuracy for tumor assessment and metabolic imaging in clinical practice through the use of [18F]FDG PET/MRI.
Abstract
BACKGROUND: Respiratory motion-induced misalignment between positron emission tomography (PET) and magnetic resonance attenuation maps remains a critical challenge in abdominal PET/magnetic resonance imaging (PET/MRI) quantification. This study evaluated the performance of a novel dual-domain motion correction strategy combining emission-domain [quiescent phase gating PET acquisition (Q.Static)] and attenuation-domain [quiescent period gating magnetic resonance attenuation correction (Q.MRAC)] approaches in enhancing standardized uptake value (SUV) accuracy in hepatic fluorine-18 fluorodeoxyglucose ([18F]FDG) imaging. METHODS: Fifty patients underwent [18F]FDG PET/MRI with two respiratory motion correction protocols: dual-domain correction (Q.Static + Q.MRAC) and conventional MRAC [conventional static PET acquisition (Static) + conventional magnetic resonance attenuation correction (C.MRAC)]. Three 3-cm-diameter spherical volumes of interest (VOIs) were positioned in the right hepatic lobe, including the upper lobe (VOI1), middle lobe (VOI2), and lower lobe (VOI3) to evaluate SUV quantification, spatial alignment of attenuation maps against end-expiratory T2-weighted imaging (T2WI), and motion correction efficacy. Analysis of variance was applied for comparisons of the mean SUV (SUVmean) across VOIs and protocols, the Kruskal-Wallis test to compare the differences in SUVmean, paired t-tests to analyze alignment metrics, and the intraclass correlation coefficient (ICC) to measure interobserver consistency. RESULTS: VOI2 demonstrated minimal SUV variability [coefficient of variation (CV) =2.29-2.55%], validating its use as a reference region as per the relevant guidelines. Respiratory motion caused consistent SUV underestimation: VOI1 underestimation relative to VOI2 was 16.4% for Q.Static + Q.MRAC and 26.3% for Static + C.MRAC, while the maximum underestimation rate for VOI3 was 11.4% for Static + C.MRAC. Q.Static + Q.MRAC reduced VOI1 underestimation by 38.9% as compared to Static + C.MRAC (P=0.006). Q.MRAC significantly improved anatomical alignment as compared to C.MRAC (P<0.001), reducing mismatch ratio by 48.7% and the mismatch area by 52.4% and 33.6% in the coronal and axial views, respectively. Eight percent of Q.MRAC acquisitions failed due to irregular breathing. CONCLUSIONS: Dual-domain motion correction (Q.Static + Q.MRAC) significantly improves SUV quantification accuracy in the upper lobe of right liver. These findings establish a foundation for achieving greater accuracy for tumor assessment and metabolic imaging in clinical practice through the use of [18F]FDG PET/MRI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- [18F]FDG brain PET-MR versus PET/CT in a clinical cohort: intra-subject quantitative comparisonsScientific Reports · 2026
- Effect of Visualized Respiratory Training on Patient Cooperation and Image Quality in Gadoxetic Acid Disodium‐Enhanced Liver MRI : A Randomized Controlled TrialJournal of Magnetic Resonance Imaging · 2026
- FDG PET/MR for liver metastases: a systematic review and meta-analysis of diagnostic accuracy and technical protocols with a proposed reporting framework.Abdominal radiology (New York) · 2026
- A two-stage PET/MRI attenuation-correction workflow for pseudo-CT and AC PET synthesis with GUI-based inference.Medical & biological engineering & computing · 2026
- Test-Retest Repeatability of [18F]FDG Uptake by Solid Tumors on PET/MRI: A Prospective, Multicenter Study Using the QIBA Protocol.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Data-Driven Respiratory Motion Correction in 18F-FDG PET for Cardiac Sarcoidosis: A Location-Dependent Phantom Study.Journal of nuclear medicine technology · 2026