Simulation of calcium blooming artifacts in coronary CT angiography from digital phantoms.
Xiaoling Wang, Guanyu Li, Shiteng Suo, Sant Kumar, Jiayue Huang, Jianhua Ma, Yongbo Wang, Xuhui Zhou,
Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. · Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Key points
From the paper's conclusion- Simulated CT images from digital phantoms resembled the acquired images by CT scanners. Tube voltages and reconstruction kernels significantly affected the extent of calcium blooming artifacts both for simulated and acquired images. The proposed framework for calcium blooming artifacts may provide an in silico testbed for improving coronary CTA interpretation.
Abstract
BACKGROUND: Calcium blooming artifacts, predominantly caused by the partial volume effect, may limit the accuracy of coronary stenosis assessment on coronary computed tomography angiography (CTA). Existing comparative tests or physical phantoms to evaluate de-blooming methods are costly, time-consuming, and limited in geometry and materials. This study developed a computational method to simulate CTA images incorporating calcified plaques from digital phantoms to help understand the characteristics of blooming artifacts. METHODS: Digital vascular phantoms with different plaque geometries and stenosis severities were created and imaged by computed tomography (CT) simulation. To assess the accuracy of simulation, CT images of three-dimensional (3D)-printed physical phantoms were acquired by CT scanners. To investigate the consistency of the impacts of tube voltage and reconstruction kernel on calcium blooming artifacts, both simulated and acquired CT images were quantitatively analyzed. RESULTS: The average structural similarity index measure (SSIM) of simulated and acquired images was 0.94±0.04. CT number, image noise and calcified area comparison between the simulated and corresponding acquired images showed good agreement. Normalized calcified area was 1.12±0.13, 1.05±0.12, 0.99±0.11 (P<0.001), for 80, 100 and 120 kV, respectively, across the simulated and acquired images. Normalized calcified area was 0.93±0.04, 0.96±0.06, 1.02±0.05, and 1.07±0.16, for reconstruction kernels from sharp to soft (P<0.001) for simulated images; result was 0.99±0.17 (sharp) vs. 1.09±0.13 (soft) for acquired images (P<0.001). Linear regression analysis indicated that measured calcified area increased as tube voltage decreased or reconstruction kernel became softer (r2>0.98) both for simulated and acquired images. CONCLUSIONS: Simulated CT images from digital phantoms resembled the acquired images by CT scanners. Tube voltages and reconstruction kernels significantly affected the extent of calcium blooming artifacts both for simulated and acquired images. The proposed framework for calcium blooming artifacts may provide an in silico testbed for improving coronary CTA interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short-Trajectory artifact-reversal diffusion for CCTA calcium deblooming.Journal of X-ray science and technology · 2026
- 5.0 T Coronary Magnetic Resonance Angiography in Calcified Coronary Arteries: Diagnostic Performance Compared With Computed Tomography Using Invasive Angiography as Reference.Journal of magnetic resonance imaging : JMRI · 2026
- Lumen imaging in calcified coronary arteries using high-resolution Gd-enhanced color K-edge imaging with spectral photon-counting CT: a phantom studyEuropean Radiology Experimental · 2026
- Deep learning-based assessment of coronary artery disease using curved-multiplanar reconstruction: comprehensive evaluation of stenosis, calcification, and plaqueEuropean Heart Journal · 2026
- Quantification of plaque and detection of high-risk plaque characteristics based on coronary computed tomography angiography: comparison between superresolution deep learning reconstruction and hybrid iterative reconstruction.Quantitative imaging in medicine and surgery · 2026
- Photon-counting computed tomography in coronary artery bypass grafting planning and follow-up: a narrative review of a high-resolution adjunct to invasive angiography.Journal of thoracic disease · 2026