Hip resurfacing arthroplasty with cemented highly cross-linked all polyethylene acetabular components.
James W Pritchett
Department of Orthopedic Surgery, Swedish Medical Center, Seattle, WA, USA.
Key points
From the paper's conclusion- Cemented all XLPE acetabular bearings produced successful clinical outcomes initially in all patients. Six (4.9%) patients required revision for acetabular failure. Anterior/superior wear was found in the retrievals, but dome wear was limited. Cementing an XLPE acetabular component is a reasonable approach in HRA, but since it does not allow adjunct screw fixation that a metal-backed two-piece component can offer, it is not a solution for every HRA.
Abstract
BACKGROUND: Hip resurfacing arthroplasty (HRA) is needed for certain patients, such as those with in situ metal work and abnormal anatomy, and/or other needs that are not well-served by total hip replacement (THR). Over the last 20 years, almost all HRAs have been performed using Metal-on-Metal (MoM) bearings, but metal wear debris generated over time has now ended their continued use. Cemented highly cross-linked polyethylene (XLPE) acetabular bearings have shown excellent survivorship for use in THR and the aim of this study is to determine if this also applied to HRA. METHODS: This prospective cohort study evaluated extending the use of cemented XLPE acetabular bearings to HRA. There were 122 HRA patients who received a cemented XLPE acetabular component. They were followed for a mean 15 years (range, 10-20 years). There were 65 women (53%) and 57 men (47%). The mean age at surgery was 49.2 years (range, 21-68 years) the mean body mass index (BMI) was 26 kg/m2. Clinical outcomes and survivorship were determined. Analyses of implants retrieved during revision or postmortem were performed to evaluate consequences of wear debris. RESULTS: The 10-year survival rate for 122 hips was 93.5% [95% confidence interval (CI): 91.7-98.1%] for all-cause revision. Six acetabular bearings failed, requiring revision for: loosening [2], polyethylene wear [2], and dislocation [2]. Four additional well-functioning XLPE bearings were retrieved postmortem. Two well-functioning cemented acetabular bearings were also retrieved; one was an explant for an infection after 9 years and the other was retrieved during revision to THR because of femoral head avascular necrosis at 6 years. Analysis of the 12 retrievals found signs of limited anterior/superior wear in all bearings along with minimal wear in the dome of 10 bearings. Only two retrieved bearings had more than 50% of the anterior/superior area worn and these were after 15 and 20 years of use. Two of the retrieved implants had no signs of wear. CONCLUSIONS: Cemented all XLPE acetabular bearings produced successful clinical outcomes initially in all patients. Six (4.9%) patients required revision for acetabular failure. Anterior/superior wear was found in the retrievals, but dome wear was limited. Cementing an XLPE acetabular component is a reasonable approach in HRA, but since it does not allow adjunct screw fixation that a metal-backed two-piece component can offer, it is not a solution for every HRA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hip resurfacing arthroplasty at a minimum of 14 years: revision is concentrated among female patients with dysplasia and small components.Archives of orthopaedic and trauma surgery · 2026
- The 10- Year Clinical and Radiographic Outcomes of a Vitamin E-Infused Highly Cross-Linked Polyethylene Cup in Total Hip Arthroplasty: A Multicenter Cohort Study.The Journal of arthroplasty · 2026
- Comparative outcomes of delta-on-delta and delta-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a nationwide cohort study.Archives of orthopaedic and trauma surgery · 2026
- FP12.6 Metal-on-Metal Hip Resurfacing in Patients 35 Years and Younger: 18-Year Survivorship and Outcomes From 184 CasesJournal of Hip Preservation Surgery · 2026
- Revision outcomes after failed hip resurfacing arthroplasty vary by failure indication and component strategy: A systematic review.Journal of experimental orthopaedics · 2026
- Association of polyethylene type with revision and dislocation risk following primary total hip arthroplasty: a population-based cohort study from the Danish Hip Arthroplasty Register.Acta orthopaedica · 2026