Evolution of thyroid fine-needle aspiration biopsy performance over 15 years: implications for risk stratification in clinical practice.
Hakan Doğruel, Elif Nur Karaoğlu, Nusret Yılmaz, Mustafa Aydemir, Hasan Çalış, Cumhur Arıcı, Güzide Ayşe Ocak, İnanç Elif Gürer,
Division of Endocrinology and Metabolism, Department of Internal Medicine, Akdeniz University Faculty of Medicine, Antalya, Turkey. · Department of General Surgery, Akdeniz University Faculty of Medicine, Antalya, Turkey.
Key points
From the paper's conclusion- The overall discriminative ability of the Bethesda System remained stable over 15 years. The decrease in the AUS/FLUS LR reflects a spectrum effect driven by more selective surgical referral patterns and should be interpreted as a change in cohort composition rather than diminished test performance.
Abstract
OBJECTIVE: We aimed to evaluate temporal changes in the diagnostic performance of thyroid fine-needle aspiration biopsy (FNAB) over a 15-year period in a single-center, surgically confirmed cohort. SUBJECTS AND METHODS: We retrospectively analyzed thyroid FNABs performed between 2009 and 2023, dividing the data into two intervals (Group 1: 2009-2014; Group 2: 2015-2023). All specimens were interpreted by the same two experienced cytopathologists. Sensitivity, specificity, and Youden's J were calculated at four diagnostic thresholds (≥AUS/FLUS, ≥FN/SFN, ≥SM, and malignant only), and level-specific likelihood ratios (LRs) were compared between cohorts. Overall diagnostic discrimination was assessed with receiver operating characteristic (ROC) curves and compared by DeLong's test. RESULTS: The study included 1,241 nodules; after excluding non-diagnostic cytology, 601 nodules in Group 1 and 553 in Group 2 were available for diagnostic performance analysis. At the ≥AUS/FLUS cutoff, sensitivity increased from 85.6% to 94.8%, while specificity declined from 58.4% to 33.0% (both p<0.01). Specificity at higher thresholds remained similar or increased in Group 2. The area under the ROC curve (AUC) was 0.799 for Group 1 and 0.831 for Group 2 (p = 0.24). Of the five Bethesda LRs, only that for AUS/FLUS changed significantly (1.24 vs. 0.37; p<0.01). CONCLUSION: The overall discriminative ability of the Bethesda System remained stable over 15 years. The decrease in the AUS/FLUS LR reflects a spectrum effect driven by more selective surgical referral patterns and should be interpreted as a change in cohort composition rather than diminished test performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical application of TBSRTC in thyroid FNAC: a single-center retrospective study.BMC endocrine disorders · 2026
- Cytomorphological spectrum of thyroid lesions using the Bethesda system: A retrospective study.Bioinformation · 2026
- Impact of Cytologist-Performed Rapid on-Site Evaluation on Adequacy and Diagnostic Performance in Thyroid Fine Needle Aspiration Cytology.Diagnostic cytopathology · 2026
- Higher adequacy rates for thyroid aspirates: impact of long-term implementation of modified Bethesda adequacy criteria on aspiration and Afirma performance.Journal of the American Society of Cytopathology · 2026
- Application of ultrasound risk stratification model combined with FNA and FNA-Tg for diagnosing cervical lymph node metastasis in papillary thyroid carcinomaWorld Journal of Surgical Oncology · 2026
- Application of fine-needle aspiration biopsy combined with multi-gene testing in the differential diagnosis of benign and malignant C-TIRADS 4 thyroid nodules.Frontiers in medicine · 2026