Comparison Between Mohindra Retinoscopy and Wet Retinoscopy in Refraction of Infants and Children.
Mousffa Abdul Ghafoor, Afia Tahir, Shahid Noor, Zaneera Hassan, Iffa Raees, Ruhullah
College of Ophthalmology and Allied Vision Sciences, King Edward Medical University, Lahore, Pakistan. · Department of Ophthalmology, Fazle Omar Hospital, Rabwah, Pakistan.
Key points
From the paper's conclusion- Wet retinoscopy yielded statistically significant differences in refractive measurements compared to Mohindra near retinoscopy in infants and children. Mohindra near retinoscopy underestimated hyperopic and astigmatic refractive errors. These findings suggest that wet retinoscopy remains the fundamental method for pediatric refractive assessment, particularly in infants and in cases of latent hyperopia.
Abstract
PURPOSE: The purpose of this study was to compare the results of Mohindra near retinoscopy and wet retinoscopy in the refraction of infants and children. METHODS: This comparative cross-sectional analytical study included 56 participants, comprising two equal groups of 28 infants and 28 children with refractive errors. Both Mohindra near retinoscopy and wet retinoscopy were performed on each infant and child. Mohindra near retinoscopy was performed first in a dark room at a distance of 50 cm with one eye occluded. Wet retinoscopy was performed after Mohindra near retinoscopy using 1% cyclopentolate hydrochloride eye drops. The Wilcoxon signed-rank test was used for comparison between the two techniques. RESULTS: The mean spherical values obtained by Mohindra near retinoscopy were 0.14 ± 2.97 D and 0.20 ± 3.04 D for the right and left eyes, respectively, whereas wet retinoscopy demonstrated higher spherical means of 0.52 ± 3.28 D and 0.58 ± 3.17 D. Statistically significant differences were observed between Mohindra near retinoscopy and wet retinoscopy for spherical measurements in the right (Z = -3.665, P < 0.001) and left (Z = -3.600, P < 0.001) eyes. Significant differences were also found in cylindrical measurements for the right (Z = -2.380, P = 0.017) and left (Z = -3.355, P = 0.001) eyes. CONCLUSION: Wet retinoscopy yielded statistically significant differences in refractive measurements compared to Mohindra near retinoscopy in infants and children. Mohindra near retinoscopy underestimated hyperopic and astigmatic refractive errors. These findings suggest that wet retinoscopy remains the fundamental method for pediatric refractive assessment, particularly in infants and in cases of latent hyperopia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Refraction Obtained with the Myopia Master and Subjective Manifest Refraction in Pediatric Orthokeratology.Diagnostics (Basel, Switzerland) · 2026
- Factors Influencing Refractive Severity and Visual Improvement in Pediatric Unilateral High Myopia With Myelinated Retinal Nerve Fibers.Eye & contact lens · 2026
- Refractive Error Centile Curves for Asian and Western Children and Adolescents: An Individual Level Meta-AnalysisInvestigative Ophthalmology & Visual Science · 2025
- Oculomotor Profiles in Children Wearing Different Myopia Control Lenses: A Real-World Eye Tracking Study.Vision (Basel, Switzerland) · 2026
- Refractive Error Measurement Comparison Between Two Techniques, HandyRef‐K Handheld Refractometer Versus Streak Retinoscopy, in Normal DogsVeterinary Ophthalmology · 2026
- Esotropia Induced by Optical Correction in Myopic Patients.Seminars in ophthalmology · 2026