Polimery w medycynie

Physical and mechanical properties of denture base acrylic resins: Comparison between CAD/CAM fabrication and water-bath and microwave heat-curing under the effects of thermocycling and disinfection.

Camila Paes Aikawa Wolff, Daniela Micheline Do Santos, Fernanda Pereira De Caxias, Marcelo Coelho Goiato

Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University (UNESP), Araçatuba, Brazil.

Key points

From the paper's conclusion
  • Aging and disinfection procedures may alter the physical and mechanical properties of denture base resins, with microwave-polymerized resins and microwave disinfection showing the greatest impact.

Abstract

BACKGROUND: PMMA-based complete dentures remain widely used in clinical practice; however, inherent limitations such as porosity, residual monomer content, and susceptibility to biofilm accumulation may compromise their long-term performance. Although CAD/CAM technology has been introduced to improve prosthesis quality and reduce structural defects, aging processes and routine disinfection protocols may still negatively affect the physical and mechanical properties of denture base materials, highlighting the importance of laboratory simulations of clinical conditions. OBJECTIVES: This study evaluated the influence of thermocycling and different disinfection protocols on the physical and mechanical properties of milled and heat-cured acrylic resins used for denture bases. MATERIAL AND METHODS: A total of 150 specimens were fabricated (n = 50 per material) using a CAD/CAM-milled resin (Vasden) and 2 heat-cured acrylic resins, processed either by water-bath heat curing (Lucitone) or microwave heat curing (Vipi-Dent). Microhardness, surface roughness, color stability, and water sorption and solubility were measured at baseline (T0), after thermocycling (2000 cycles between 5 ±1°C and 55 ±1°C), and after disinfection (T1). Disinfection protocols included 4% chlorhexidine, 1% sodium hypochlorite, effervescent cleansing tablets, neutral soap, and microwave irradiation. Each material group was subdivided into 5 subgroups (n = 10) according to the disinfection protocol. RESULTS: Microhardness was significantly influenced by time, material type, and disinfection protocol. Surface roughness was affected by material and disinfection protocol, but not by time. Color stability was influenced by all evaluated factors, with microwave disinfection producing clinically unacceptable changes. Water sorption and solubility increased over time in all materials and were also affected by the disinfection protocol. CONCLUSIONS: Aging and disinfection procedures may alter the physical and mechanical properties of denture base resins, with microwave-polymerized resins and microwave disinfection showing the greatest impact.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers