Cytotoxic Effects of Milled, 3D-Printed, and Conventional Methacrylate-Based Resins After Exposure to Denture Cleansers: A Preliminary In Vitro Screening Study.
Rumeysa Bayram Büyükokuroğlu, Gülsüm Sayın Özel
Department of Prosthodontics, School of Dentistry, Istanbul Medipol University, Istanbul 34810, Türkiye.
Key points
From the paper's conclusion- This study evaluated cellular responses to extracts of CAD/CAM-milled PMMA, 3D-printed methacrylate-based resin, and conventionally heat-polymerized PMMA after denture cleanser exposure.
Abstract
This study evaluated cellular responses to extracts of CAD/CAM-milled PMMA, 3D-printed methacrylate-based resin, and conventionally heat-polymerized PMMA after denture cleanser exposure. Specimens (MTT, n = 240; BrdU, n = 36) were assigned to Corega, chlorhexidine, Listerine, or distilled water. Following accelerated cumulative exposure (1825 min; not simulating clinical use), extracts were applied to human gingival fibroblasts. Cellular metabolic activity was assessed by MTT absorbance, DNA synthesis-associated proliferative activity by quantitative BrdU immunofluorescence, and morphology and F-actin organization qualitatively. Material and cleansing solution significantly affected MTT absorbance (both p < 0.001), with a significant interaction (p = 0.008). CAD/CAM-milled and 3D-printed materials exhibited higher MTT absorbance than conventional PMMA (p < 0.001 and p = 0.003, respectively), without a significant difference between them (p = 0.071). Distilled water yielded higher MTT absorbance than all cleansers (all p < 0.001). BrdU labeling showed a significant cleansing solution effect (p < 0.001) but no significant material effect or interaction. In this preliminary screening study, cleansing solution affected both metabolic and DNA synthesis-associated responses, whereas material differences were significant only for MTT absorbance. Mechanisms were not investigated; the milled material (TEMPO-CAD) is not primarily a denture base material, so findings should not be generalized.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of denture cleansing solutions on physical properties of 3D-printed and heat-polymerized denture base resinsBMC Oral Health · 2026
- In Vitro Cytotoxicity of Three Dimethacrylate-Based Photopolymer Resins for 3D-Printed Dental Restorations: A Qualitative Morphological Screening on Human Fibroblasts.Journal of functional biomaterials · 2026
- Residual monomers and volatile leachable substances of conventional and CAD/CAM-fabricated denture base materials — GC-MS analysis and surface characterizationClinical Oral Investigations · 2026
- Comparative Evaluation of Effect of Surface Roughness on Microbial Adhesion to Milled, 3D-Printed, and Conventional PMMA Denture Base Resin: An In Vitro Study.International journal of dentistry · 2026
- Effects of chemical and mechanical cleaning methods on the surface, physicochemical, and microbiological properties of extrinsically characterized 3D-printed denture base resins after exposure to different pigmenting solutions.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- In-vitro Comparison of Residual Monomer Content and Water Sorption of Printed, Milled and Conventional Heat-Cured Poly Methylmethacrylate Denture Base Resin.The International journal of prosthodontics · 2026