Fundus camera and artificial intelligence for diabetic retinopathy screening in a São Paulo shelter.

Julia Gimenes da Silva Dias, Gabriel Costa de Andrade, João Victor Tenório Lossio de Macedo, Andrezza Soldera Graziano

Irmandade da Santa Casa de Misericórdia de São Paulo - São Paulo (SP), Brazil. · Irmandade da Santa Casa de Misericórdia de São Paulo, Department of Ophthalmology - São Paulo (SP), Brazil.

Key points

From the paper's conclusion
  • The Eyer® device demonstrated operational feasibility for ocular screening by trained non-ophthalmologists. The high prevalence of media opacities and non-diabetic retinopathy conditions compromised artificial intelligence performance, highlighting the need for broader screening strategies in elderly and socially vulnerable populations.

Abstract

OBJECTIVE: The aim of this study was to evaluate the applicability of a smartphone-based portable fundus camera for diabetic retinopathy screening in elderly residents of a specialized shelter in São Paulo, Brazil, considering image acquisition by non-ophthalmologist professionals and remote case classification. METHODS: Prospective pilot interventional study at the Centro de Acolhida Especial para Idosos Morada São João. Thirty-eight participants (76 eyes) underwent retinal imaging using the Eyer® portable fundus camera (Phelcom Technologies, Brazil) by trained non-ophthalmologist professionals. Images were remotely evaluated by a retinal specialist and compared to the EyerMaps® artificial intelligence system. RESULTS: Mean age was 71.6±7.0 years; 78.9% male. Fifteen participants (39.5%) had confirmed diabetes mellitus. The specialist identified abnormalities in 70 of 76 eyes (92.1%), most frequently glaucoma suspicion, media opacity suggestive of cataract, chorioretinal changes, and age-related macular degeneration signs; no diabetic retinopathy was identified. Against the specialist's assessment of any ocular abnormality as the reference standard, the artificial intelligence system classified 22 eyes as abnormal, yielding sensitivity 25.7% (95%CI 16.9-37.0), specificity 33.3% (95%CI 9.7-70.0), positive predictive value 81.8% (95%CI 61.5-92.7), negative predictive value 3.7% (95%CI 1.0-12.5), and overall accuracy 26.3% (95%CI 17.7-37.2). CONCLUSION: The Eyer® device demonstrated operational feasibility for ocular screening by trained non-ophthalmologists. The high prevalence of media opacities and non-diabetic retinopathy conditions compromised artificial intelligence performance, highlighting the need for broader screening strategies in elderly and socially vulnerable populations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.