Cross-reactivity Test of Commercial Rotavirus and Adenovirus Antigen Detection Kits with Enteric Bacterial Strains
Soyun Kim, M.C. Jung, Sohyeong Kim, Sunghyun Kim, Choseung Kim, Heechul Park, Sunghyun Kim
Catholic University of Pusan · Hyejeon College
Key points
From the paper's conclusion- Infectious gastroenteritis can be caused by viral, bacterial, or parasitic pathogens, and accurate identification of the causative agent is essential for appropriate treatment.Rotavirus and adenovirus antigen detection kits are widely used for the rapid diagnosis of viral gastroenteritis; however, if these assays do not possess sufficient specificity to distinguish target pathogens from nontarget
Abstract
Infectious gastroenteritis can be caused by viral, bacterial, or parasitic pathogens, and accurate identification of the causative agent is essential for appropriate treatment.Rotavirus and adenovirus antigen detection kits are widely used for the rapid diagnosis of viral gastroenteritis; however, if these assays do not possess sufficient specificity to distinguish target pathogens from nontarget pathogens, diagnostic accuracy may be compromised.This study evaluated the potential cross-reactivity of rotavirus and adenovirus antigen detection kits with reference to strains of common enteric pathogenic bacteria.Eight bacterial reference strains, Escherichia coli O157:H7, Shigella dysenteriae, Shigella flexneri, Shigella sonnei, Salmonella enterica subsp.enterica serovar Paratyphi A, S. enterica subsp.enterica serovar Typhi, S. enterica subsp.enterica serovar Agona, and S. enterica (serogroup B) strains, were cultured and adjusted to a 0.5 McFarland standard.Samples were analyzed using a conventional rapid antigen detection kit and a fluorescence immunoassay (FIA)-based rotavirus and adenovirus antigen detection kit with a STANDARD F2400 analyzer.All bacterial strains tested negative in both diagnostic assays.A fluorescent signal of 0.67 was observed for E. coli O157:H7 in a single FIA measurement; however, this value was below the positivity cut-off value of 1.0, and repeated analysis yielded a value of 0.00.Furthermore, none of the tested strains exceeded the positive threshold in either assay.These findings demonstrated that the evaluated rotavirus and adenovirus antigen detection kits did not exhibit detectable cross-reactivity with the tested bacterial enteric pathogens, supporting their analytical specificity for the diagnosis of viral gastroenteritis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enteric Pathogens in children under five with diarrhoea in a rotavirus vaccinated population in Coastal Ghana, 2023.PloS one · 2026
- First isolation and characterisation of human Rotavirus alphagastroenteritidis from cerebrospinal fluid in Malaysia.Virus genes · 2026
- Assessment of BioFire Gastrointestinal Panel unconfirmed positive results for enteropathogenic bacteria and Norovirus and accuracy of a post-analytical algorithm to mitigate unconfirmed results.Journal of clinical microbiology · 2026
- A high-throughput rotavirus neutralization assay quantifies antibody responses beyond serum IgA in human infants.The Journal of general virology · 2026
- Exploring the role of rotavirus, adenovirus, and norovirus in gastroenteritis among children in Iraq: an epidemiological and molecular studyFrontiers in Virology · 2026
- Molecular Detection of Gastrointestinal Pathogens Using a Multiplex Gastrointestinal Panel and Their Associations With Demographic and Clinical Characteristics.Cureus · 2026