From the paper's conclusion
  • We validated the technical performance and practical utility of this assay using 142 archived serum samples from a clinical trial cohort of Zambian infants vaccinated with either oral Rotarix (G1P[8]) or a parenteral non-replicating rotavirus vaccine candidate.

Abstract

Rotavirus remains a leading cause of severe childhood gastroenteritis worldwide, yet the immune correlates of protection have been challenging to define. Here, we present an updated, high-throughput fluorescent imaging-based assay to quantify neutralization of rotavirus by antibodies prior to virus entry into cells. This methodology enables sensitive and reproducible assessment of rotavirus-specific antibody function in clinical samples within 24 h. By coupling fluorescent-focus detection after a single round of viral replication with automated multi-channel high-content imaging and cell-counting pipelines, this methodology significantly increases throughput, accuracy and cellular quality control compared to traditional neutralizing ELISAs (nELISAs). We also verified that widely accessible fluorescent ELISpot plate readers can accurately quantify fluorescent foci, expanding the potential availability of this methodology. We validated the technical performance and practical utility of this assay using 142 archived serum samples from a clinical trial cohort of Zambian infants vaccinated with either oral Rotarix (G1P[8]) or a parenteral non-replicating rotavirus vaccine candidate. The automated fluorescent-focus readout demonstrated high reproducibility (R2§amp;gt;0.90), extended dynamic range and strong comparability to standard nELISA outputs. Parallel evaluations against serum IgA titres confirmed that high-throughput neutralization measurements capture functional antibody dynamics distinct from total binding IgA. This highlights the assay's value as a robust tool for comprehensive immunogenicity profiling and vaccine candidate evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A high-throughput rotavirus neutralization assay quantifies antibody responses beyond serum IgA in human infants — Science Skim