Pitfalls in lung subtraction CT: delayed contrast acquisition causes underestimation of pulmonary perfusion in a canine model.
Kentaro Yamazaki, Kosei Teraoka, Masayoshi Nagakawa, Chiharu Ito, Akari Taniguchi, Kodai Tashiro, Kazuya Kushida, Kija Lee,
Cooperative Division of Veterinary Sciences, Tokyo University of Agriculture and Technology. · Cooperative Department of Veterinary Medicine, Tokyo University of Agriculture and Technology.
Key points
From the paper's conclusion- In conclusion, delayed acquisition resulted in underestimation of pulmonary perfusion on LSCT images.
Abstract
Lung subtraction computed tomography (LSCT), assessing pulmonary perfusion by subtracting non-contrast-enhanced images from contrast-enhanced images, may underestimate pulmonary perfusion when contrast-enhanced image acquisition is delayed. This study aimed to evaluate the effects of delayed acquisition of contrast-enhanced images on the LSCT assessment of pulmonary perfusion and identify indicators of sufficient contrast enhancement for LSCT generation using healthy beagles. Five beagles underwent continuous cine computed tomography (CT) for 30 s. After the second scan, iodixanol was intravenously administered. LSCT images were generated by subtracting pre-contrast images from contrast-enhanced images. On LSCT images, lung CT values and the percentage of areas with CT values of 0-20 HU were measured at the pulmonary trunk and tracheal bifurcation levels when the lung CT value on LSCT images was the highest and at 1.5 and 3.0 s thereafter. Pulmonary trunk CT values and pulmonary trunk-to-aorta (Pa/Ao) CT value ratios were recorded. Lung CT values decreased significantly over time, whereas the percentages of 0-20 HU areas increased. Pulmonary trunk CT values were associated positively with lung CT values and negatively with the percentages of 0-20 HU areas at both slice levels. Pa/Ao ratios showed similar significant associations at the pulmonary trunk level but not at the tracheal bifurcation level. In conclusion, delayed acquisition resulted in underestimation of pulmonary perfusion on LSCT images. These findings highlight the importance of appropriate acquisition timing. Pa/Ao ratios might indicate whether contrast enhancement is sufficient for LSCT generation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-Specific Timing for Pulmonary CT Angiography: Human Validation of a Physiologically Derived Post-Trigger Delay Model.Diagnostics (Basel, Switzerland) · 2026
- Enhancement of Lung Parenchyma and Pulmonary Lobar Vessels Following Iodinated Contrast Injection in Healthy Cats Undergoing Thoracic Computed Tomography.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2026
- Plasma Lipocalin-2 and Echocardiographic Indices After Isolated Right Pulmonary Artery Ligation in Rats: Associations with Right Ventricular Systolic Pressure and Histologic Remodeling.Journal of cardiovascular development and disease · 2026
- Feasibility and characteristics of contrast-enhanced lung ultrasound in the diagnosis of pulmonary embolism in hospitalized patients.Medicina clinica · 2026
- Anatomy- and Time-Based Post-Processing with CT Perfusion-Derived Time-Vessel Maps to Reduce Incorrect Occlusion Detections in Late-Phase CT Angiography.Diagnostics (Basel, Switzerland) · 2026
- Diagnoses of pulmonary embolism from non-contrast 4DCT using image processing-derived quantitative perfusion scoresnpj Biomedical Innovations. · 2026