Would Body Mass Index Affect Measurement and Prognostic Value of Remote Dielectric Sensing (ReDS) in Heart Failure?
Ting Liu, Yingjing Xie, Xiu Zhang, Yu Kang, Zixuan Yang, Xiaojing Chen, Qing Zhang
Department of Cardiology, West China Hospital of Sichuan University. · Rehabilitation Medical Center, West China Hospital of Sichuan University.
Key points
From the paper's conclusion- Therefore, we aimed to investigate the correlation between BMI and ReDS with its prognostic value across BMI categories in patients hospitalized for acute decompensated heart failure (ADHF).We prospectively enrolled 172 ADHF patients (median age: 62 years, 65.1% male).
Abstract
Remote Dielectric Sensing (ReDS) non-invasively quantifies pulmonary congestion and is recommended for patients with BMI 22.0-39.0 kg/m2. This range may not fully represent Chinese heart failure (HF) populations, and it remains unclear whether BMI affects ReDS measurement. Therefore, we aimed to investigate the correlation between BMI and ReDS with its prognostic value across BMI categories in patients hospitalized for acute decompensated heart failure (ADHF).We prospectively enrolled 172 ADHF patients (median age: 62 years, 65.1% male). ReDS was measured within 24 hours before discharge. Patients were stratified by Chinese BMI criteria: underweight (< 18.5), normal-overweight (18.5-27.9), and obese (≥ 28.0 kg/m2). The primary endpoint was a composite of HF rehospitalization or cardiovascular death at 1 month.ReDS values correlated positively with BMI (r = 0.487, P < 0.001) while the average ReDS value differed between the BMI groups (underweight versus normal-overweight versus obese: 24 ± 6 versus 30 ± 6 versus 34 ± 6%, P < 0.001). Adjusted for BMI, each unit of ReDS increase independently predicted adverse outcomes (HR = 1.09, P = 0.039). In the patient group within manufacturer-recommended BMI range (n = 91), a ReDS > 35% showed no increased risk (HR = 1.07, P = 0.226). However, in the Chinese normal-overweight group (18.5-27.9 kg/m2, n = 122), a ReDS > 35% predicted the composite endpoint (31.8% versus 11.0%, P = 0.021; HR = 3.30, P = 0.014). BMI-corrected ReDS consistently outperformed the uncorrected values in multivariable models.BMI may confound ReDS measurement. Although it is useful for risk stratification in ADHF, ReDS interpretation should account for BMI to enhance its clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Remote Dielectric Sensing for Pulmonary Congestion Assessment: Current Concepts and Clinical Perspectives.ESC heart failure · 2026
- Short-term decongestion and clinical benefit in acute heart failure: a systematic review and trial-level meta-regression.Frontiers in cardiovascular medicine · 2026
- Advances in Congestion Assessment in Decompensated Heart FailureCardiac failure review · 2026
- Diagnostic performance and 3-month prognostic impact of multimodal assessment of residual congestion at discharge in acute heart failureEuropean Heart Journal · 2026
- Modified Venous Excess Ultrasound (mVExUS) Grades and CA125 Levels in Acute Decompensated Heart Failure.Medicina (Kaunas, Lithuania) · 2026
- Subclinical pulmonary congestion provides further risk stratification in heart failure patients at dischargeEuropean Heart Journal · 2026