ESC heart failure

Remote Dielectric Sensing for Pulmonary Congestion Assessment: Current Concepts and Clinical Perspectives.

Teruhiko Imamura

The Second Department of Internal Medicine, University of Toyama, Japan.

Review

Key points

From the paper's conclusion
  • Remote dielectric sensing should be considered a complementary component of multimodality congestion assessment.

Abstract

Pulmonary congestion is a major determinant of symptoms, hospitalisation, and prognosis in cardiovascular disease, yet its quantitative assessment remains challenging. Remote dielectric sensing is a non-invasive electromagnetic method that provides a quantitative estimate of pulmonary fluid content within approximately one minute. This narrative review summarizes the principles, validation, clinical interpretation, applications, and limitations of remote dielectric sensing. In a validation study of 46 hospitalised patients, including 28 with heart failure, remote dielectric sensing correlated with computed tomography-derived high-attenuation lung area (r=0.65, P<0.001). In a prospective study of 153 patients with heart failure, remote dielectric sensing correlated with lung ultrasound B-line count (r=0.544); a threshold of 34.5% identified lung ultrasound-defined pulmonary congestion with an area under the curve of 0.748, sensitivity of 73.5%, and specificity of 70.2%. In 133 patients hospitalised with acute heart failure, with a median age of 78 years, 59% men, and a median left ventricular ejection fraction of 57%, an increase in remote dielectric sensing from admission to discharge was associated with all-cause death or heart failure rehospitalisation (adjusted hazard ratio 4.37, 95% confidence interval 1.13-16.81). In a proof-of-concept randomised trial of 100 patients hospitalised with acute decompensated heart failure, the primary endpoint occurred in 2% with remote dielectric sensing-guided care versus 20% with routine care (hazard ratio 0.094). Available evidence supports diagnostic validity and potential prognostic value, but external validation remains limited. Evidence that remote dielectric sensing-guided management improves clinical outcomes remains preliminary. Remote dielectric sensing should be considered a complementary component of multimodality congestion assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Remote Dielectric Sensing for Pulmonary Congestion Assessment: Current Concepts and Clinical Perspectives — Science Skim