Low-cost methodologies for evaluating the cleaning performance of commercial medical device detergents using commercially available photographic film strip and simulated dried red blood soil
Phuong V. Dau, Abhigyan Som, Ann-Margret Andersson
Key points
From the paper's conclusion- The findings also indicated that the cleaning performance of medical device detergents can be significantly influenced by formulation components other than enzymes, such as surfactants.
Abstract
The cleaning performance of a series of commercially available non-enzymatic and enzymatic detergents were evaluated based on their ability to break down gelatin layers in photographic film and to remove simulated dried blood soil. Both methods presented are simple methodologies with quick turn-around-time for screening the cleaning performance of detergents. The results also showed that there is no significant difference in the performance between non-enzymatic and enzymatic detergents under the test conditions. In addition, neutral to slightly basic pH detergents were found to potentially be more effective in cleaning simulated dried blood soil in comparison with alkaline detergents. The findings also indicated that the cleaning performance of medical device detergents can be significantly influenced by formulation components other than enzymes, such as surfactants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison between two methods of cleaning and disinfection of digital pulse oximeters in primary care.Revista brasileira de enfermagem · 2026
- The comparison of excision, swabbing, tape-lifting, and scraping as techniques for DNA evidence recovery: A preliminary studyForensic Science International Synergy · 2026
- Luminal Visualization versus White Swab Detection for Residual Contamination: A Single-Center Study at a Chinese Tertiary Hospital.The Journal of hospital infection · 2026
- Comparative evaluation of tandem dispersive and modified hollow fiber liquid-phase microextraction techniques for sensitive determination of NSAIDs in complex biological matricesChinese Journal of Analytical Chemistry · 2025
- Overcoming challenges in the chemical analyses of wound dressings: a practical approach based on solvent compatibility.Regulatory toxicology and pharmacology : RTP · 2026
- Geraniol Vapor Disinfection of Historical Textiles: Assessment of Physicochemical Changes in Cellulosic Materials.Materials (Basel, Switzerland) · 2026