Determinants of bone fragility: chitosan–TiO 2 -modified ELISA surface for enhanced detection of CTX-I
Yuxuan Zhang, Wenji Wang
Key points
From the paper's conclusion- Methods This study reports a highly sensitive and selective titanium oxide (TiO 2 ) nanoparticle-modified ELISA for the detection of bone resorption biomarker, C-terminal telopeptide of type I collagen (CTX-I).
Abstract
Objectives Osteoporosis is a silently developing condition marked by decreasing the bone mineral density, leads to bone fragility. Diagnosis of osteoporosis is critical, and the conventional radiological techniques are costly, makes difficult to access for routine monitoring. Therefore, researchers are using blood-based biomarkers for identifying osteoporosis, to be convenient and cheaper. Methods This study reports a highly sensitive and selective titanium oxide (TiO 2 ) nanoparticle-modified ELISA for the detection of bone resorption biomarker, C-terminal telopeptide of type I collagen (CTX-I). Chitosan-TiO 2 modification increases the area of polystyrene ELISA (PS) surface and facilitates more anti-CTX-I immobilization for robust interaction with CTX-I. Results With proper orientation of biomolecules on the above surface increases the signal generation and lowers the detection limit of CTX-I to 0.05 ng/mL. Besides, the nanomaterial-modified ELISA exhibits higher selectivity, confirmed through CTX-I-spiked detection in serum and tested with relevant control proteins, BSA, CTX-II, and N-terminal telopeptide of type I collagen (NTX). Conclusions This surface-enhanced ELISA offers a promising alternative for CTX-I detection at its lower level and helps monitoring the disease progression and therapeutic response, besides, it require further clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-395 From Bench to Bedside: Do Biosensors Match ELISA and ECLIA in Measuring PINP and CTX for Osteoporosis?Clinical Chemistry · 2026
- Xylosyltransferase-I serum activity is a promising biomarker for postmenopausal osteoporosis.Scientific reports · 2026
- Superhydrophilic Hierarchical Anatase Coating on Sandblasted, Acid-Etched Titanium: In Vitro Apatite Formation and Osteoblast Responses and the Role of Polar Surface Free EnergyJournal of Functional Biomaterials · 2026
- Smart Implant Coating with Pathological-Microenvironment-Driven Drug and Nanozyme Delivery for Osteoporotic Bone Healing.ACS applied materials & interfaces · 2026
- Lysosomal peroxynitrite imaging reveals oxidative stress and therapeutic response in osteoarthritis using a fluorogenic probe.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- ROS‐Responsive Titanium Implant Coatings Enhance Osteoporotic Osseointegration via Microenvironment Remodeling and Mitochondrial RepairAdvanced Functional Materials · 2025