A-395 From Bench to Bedside: Do Biosensors Match ELISA and ECLIA in Measuring PINP and CTX for Osteoporosis?

Aylin Sepici Dincel, Rabia Semsi, Gunay Afandiyeva, V Ercan Dincel

Key points

From the paper's conclusion
  • Conclusion Finally, biosensors demonstrate sufficient performance in measuring PINP, facilitating their transition from the laboratory to clinical settings; however, the considerable discrepancies observed in CTX measurements indicate that this technology requires extensive analytical and clinical validation before integration into routine clinical practice.

Abstract

Background Procollagen type I N-terminal propeptide (PINP) and type I collagen C-terminal telopeptide (CTX) are recommended biomarkers of bone turnover for use as reference markers in clinical research and monitoring osteoporosis treatment. In order to measure the serum/plasma levels of both tests, enzyme-linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA) are used methods for research and in routine laboratory practice. Recently developed electrochemical biosensors based on antibody immobilization and specific antigen-antibody recognition mechanisms show promise for point-of-care testing applications due to their rapid analysis times and low sample volume requirements. This study aims to evaluate the performance of these biosensors in measuring PINP and CTX in an osteoporosis patient group, compared to ELISA and ECLIA. Methods PINP (ng/mL) and CTX (pg/mL) levels were measured in serum samples of individuals diagnosed with osteoporosis using ELISA, ECLIA, and an antibody-functionalized electrochemical biosensor system that has a pending patent number of PCT/TR2025/051762 titled “Biosensor for determining biochemical index of bone status from body fluids”. Methods were compared using correlation analysis, Bland–Altman analysis, and Passing–Bablok regression. Differences among the three methods were evaluated using repeated measures ANOVA and the Friedman test. Results For PINP measurements (n=41), the biosensor demonstrated excellent agreement with ELISA and strong agreement with ECLIA. Bland–Altman analysis showed a low mean bias of -0.3590 with narrow limits of agreement (-3.3681 to 2.6481) for ELISA, while Passing–Bablok regression indicated no significant bias and a strong correlation (r=0.992, p<0.0001). In comparison, the ECLIA analysis revealed a mean bias of -1.2902 but maintained a strong correlation (r = 0.971, p<0.0001), confirming high analytical concordance for PINP. In contrast, CTX measurements (n=41) exhibited greater variability. The ELISA comparison revealed a mean bias of 3.5451 with wider limits of agreement (-41.0571 to 48.1473), indicating both systematic and proportional bias. Passing–Bablok regression demonstrated a strong correlation (r=0.998, p<0.0001) but also highlighted variability. The ECLIA comparison for CTX showed a mean bias of -18.2980 with extensive limits of agreement, suggesting limited clinical interchangeability despite a strong correlation (r = 0.978, p<0.0001). Although the biosensor demonstrated strong performance in measuring PINP, CTX analysis showed greater variability. Conclusion Finally, biosensors demonstrate sufficient performance in measuring PINP, facilitating their transition from the laboratory to clinical settings; however, the considerable discrepancies observed in CTX measurements indicate that this technology requires extensive analytical and clinical validation before integration into routine clinical practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-395 From Bench to Bedside: Do Biosensors Match ELISA and ECLIA in Measuring PINP and CTX for Osteoporosis? — Science Skim