Journal of perinatal medicine

Characterization of cervical softness using strain and shear-wave elastography techniques and its association with spontaneous preterm birth.

Edgar Hernandez-Andrade, Roberto Romero, Arun Meyyazhagan, Hyunyoung Ahn, Eun Jung Jung, Amir Gandjbakhche, Tinnakorn Chaiworapongsa, Awoniyi Awonuga,

Pregnancy Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, United States Department of Health and Human Services, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD, USA. · Section on Translational Biophotonics, Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD), National Institutes of Health, Bethesda, MD, USA.

Key points

From the paper's conclusion
  • Agreement between StE and SWE for characterizing cervical softness was poor. SWE showed stronger associations with sPTB and higher specificity than StE.

Abstract

OBJECTIVES: To compare strain (StE) and shear-wave elastography (SWE) for characterizing cervical softness and assessing their associations with spontaneous preterm birth (sPTB). METHODS: We evaluated 781 consecutive patients with singleton pregnancies at 16-26 weeks of gestation. Two consecutive transvaginal ultrasounds assessed cervical length (CL) and StE, followed by SWE. Cervical softness was assessed in a cross-sectional image at the internal cervical os, and defined as StE ≥75th percentile or shear-wave velocity ≤25th percentile for gestational age. Associations with sPTB <37 + 0 and ≤34 + 0 weeks/days of gestation, and predictive performance, were evaluated. RESULTS: Agreement between SWE and StE was poor (weighted Cohen's kappa=0.085; 95 % CI, 0.03-0.14). A soft cervix by SWE was associated with sPTB <37 + 0 weeks/days (adjusted odds ratio [aOR], 2.57; 95 % CI, 1.32-5.01; p=0.006) and with sPTB ≤34 + 0 weeks/days (aOR, 5.24; 95 % CI, 1.85-14.85; p=0.0018). No significant associations were observed for StE (sPTB <37 + 0 weeks/days: aOR, 1.56; 95 % CI, 0.81-3.02; p=0.2; sPTB ≤34 + 0 weeks/days: aOR, 1.77; 95 % CI, 0.69-4.85; p=0.2). Sensitivity did not differ significantly between techniques, whereas SWE demonstrated significantly higher specificity. Combining short CL with cervical softness by SWE reduced the number of patients classified as at risk by approximately 50 %, without missing any sPTB cases ≤34 + 0 weeks/days identified by CL alone. CONCLUSIONS: Agreement between StE and SWE for characterizing cervical softness was poor. SWE showed stronger associations with sPTB and higher specificity than StE.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers