Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study.

Yuxuan Ding, Yuan Wang, Yutian Chen, Mo Liu, Chenyan Dai, Lan Yang, Yan Xu

Department of Obstetrics and Gynecology, Affiliated Hospital of Medical School, Nanjing Drum Tower Hospital, Nanjing University, Nanjing, China. · Department of Obstetrics and Gynecology, Affiliated Hospital of Medical School, Nanjing Drum Tower Hospital, Nanjing University, Nanjing, China. yl1986_fight@163.com.

Observational

Key points

From the paper's conclusion
  • Our study establishes reference ranges for cervical viscoelastic parameters in the first and second trimesters thereby providing new quantitative tools and reference data for assessing the cervix during pregnancy. Their clinical value is yet to be determined.

Abstract

BACKGROUND: The etiology of preterm birth is complex and multifaceted, involving factors such as preterm cervical softening and remodeling, which poses challenges for prediction. Ultrasound, as a convenient and non-invasive tool, is commonly used to assess the cervix during pregnancy. However, cervical length measurement has limited accuracy in predicting preterm birth, highlighting the urgent need for more specific indicators to evaluate the cervix during gestation. OBJECTIVES: This study aimed to investigate regional differences in cervical viscoelastic parameters, evaluate their changes between the first and second trimesters using paired statistical tests, and explore their association with cervical length via ultrasound viscoelastic imaging, thereby providing a foundation for future research on preterm birth prediction. STUDY DESIGN: A prospective cohort trial enrolled pregnant women undergoing prenatal examinations at Nanjing Drum Tower Hospital from May 2024 to October 2025. Viscoelastic parameters (shear elastic modulus, viscosity coefficient, and dispersion coefficient) were measured at the internal, middle, and external segments of both the anterior and posterior cervical lips by a Mindray Resona R9 ultrasound system equipped with a 7-9 MHz transvaginal probe at 11-13⁺⁶ weeks and 22-24⁺⁶ weeks of gestation. Viscoelasticity is an indicator for evaluating the intrinsic properties of tissue; higher values indicate stiffer and more viscous tissue. RESULTS: From the first to the second trimester, the mean of all viscoelastic measurements of the anterior and posterior cervical lips decreased significantly (P < 0.0001). Within each trimester, values were highest in the internal, intermediate in the middle, and lowest in the external segment (P < 0.01). Corresponding regions of the posterior lip consistently exhibited higher values than those of the anterior counterparts (P < 0.01). Cervical length showed a very weak positive correlation with some viscoelastic parameters in the first trimester, whereas a negative correlation emerged in the second trimester. All measurements demonstrated good intra- and inter-observer reproducibility (intraclass correlation coefficient, ICC > 0.75). CONCLUSIONS: Our study establishes reference ranges for cervical viscoelastic parameters in the first and second trimesters thereby providing new quantitative tools and reference data for assessing the cervix during pregnancy. Their clinical value is yet to be determined.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers