Reheat pressure influence on the performance of steam Rankine power cycles, and an introduced level of reheat (LOR) normalized variable
Osama A. Marzouk
Key points
From the paper's conclusion- We introduce a normalized “level of reheat (LOR)” variable and show that it has a very different impact on the cycle’s efficiency versus the cycle’s effectiveness.
Abstract
We quantitatively investigate the general influence of the reheat pressure on the performance of the steam Rankine cycle with reheat, over a broad range from 1 to 120 bar (absolute reheat pressure). We computed the response curves of seven performance variables as the reheat pressure changes while keeping some cycle parameters at constant values that are typical for subcritical vapor power thermodynamic power plants (namely: 7.5 kPa absolute condenser pressure, 125 bar absolute boiler pressure, and 500 °C final superheating and reheating temperatures; or a 12.5 MPa/500 °C/500 °C cycle). We proposed a regression model for each performance variable based on a balanced selection that does not suffer from either underfitting or overfitting. The seven response variables are: (1) specific total input heat, (2) specific rejected heat, (3) specific net output shaft work, (4) thermal cycle efficiency, (5) steam dryness fraction (or steam vapor quality) at the high-pressure (HP) turbine exit, (6) steam dryness fraction at the intermediate-pressure (IP) turbine exit, and (7) specific entropy generation. We introduce a normalized “level of reheat (LOR)” variable and show that it has a very different impact on the cycle’s efficiency versus the cycle’s effectiveness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pressure Ratio and Internal Staging Selection in an Intercooled Reheat Regenerative Brayton Power Cycle: Thermodynamic, Exergy, and Cost‐Based Design MapsJournal of Thermal Science and Engineering Applications · 2026
- A High-Pressure Drum-Evaporators in Combined Cycle Power Plants Hybrid Thermodynamic Modelling and Calibration Framework for simulation of cyber-physical threatsJournal of Physics: Conference Series · 2026
- Performance Improvement and Repowering Strategies for an Existing Sugarcane Cogeneration Plant: Energy, Exergy, Economic and Environmental AssessmentEnergies · 2026
- An Error Budget for the SRK and PR Equations of State: α-Function Parameterization and Volume Translation in a Reproducible Pure-Fluid Saturation-Property BenchmarkThermo · 2026
- Off-Design Optimization of Engine-Organic Rankine Cycle System for Low-Temperature Waste Heat RecoveryJournal of energy resources technology. · 2026
- Performance Optimization and Experimental Investigation of Organic Rankine Cycle System Using Binary Zeotropic MixturesJournal of energy resources technology. · 2025