Influence of leaflet thickness on deformation behavior of a 3D-printed training heart valve for an implantation training bench
Robert Thiel, Joel Focking, Nico Beyer, Jens Jäkel, Faouzi Derbel
Key points
From the paper's conclusion- This experimental-computational framework demonstrates that macroscopic geometric tuning effectively replicates realistic valve behavior in synthetic surgical training simulators.
Abstract
High-fidelity physical simulators are essential for transcatheter aortic valve implantation (TAVI) training. While additive manufacturing enables patient-specific fabrication, standard isotropic 3D-printing materials (e.g., Formlabs Elastic 50A Resin) fail to replicate the anisotropic biomechanics of native valves. Consequently, direct geometric replication causes synthetic stenosis and unphysiological flow resistance. To overcome this, we developed an automated computational pipeline to optimize the leaflet thickness of a 3Dprinted aortic valve. The geometry is parameterized via analytical tensor-product B-spline surfaces, ensuring exact offsets and robust conformal discretization. Non-linear shell simulations (CalculiX) were driven by experimentally characterized material properties (E = 2.0 MPa) and boundary conditions acquired from a mock circulatory loop. A systematic parametric grid search mapped the inverse relationship between leaflet thickness and systolic Geometric Orifice Area (GOA). The optimization identified an ideal thickness (t*= 0.8 mm) that structurally compensates for isotropic material stiffness, restoring physiological opening kinematics. This experimental-computational framework demonstrates that macroscopic geometric tuning effectively replicates realistic valve behavior in synthetic surgical training simulators.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Fabrication of 3D-Printed Biomimetic Fiber-Reinforced Polymeric Aortic Valves for Improved Stress Distribution.Annals of biomedical engineering · 2026
- Experimental study of TPU and SEBS additively manufactured leaflets for novel aortic valve polymer TAVI prosthesis.Frontiers in bioengineering and biotechnology · 2026
- In silico modeling of transcatheter heart valve oversizing and ellipticity, Part I: Establishing credibility of an advanced modelComputer Methods and Programs in Biomedicine · 2026
- Optimization of the Nitinol Framework of an Aortic Valve Bioprosthesis Using Numerical Simulation.Sovremennye tekhnologii v meditsine · 2026
- On analytical evaluation of radial and bending stiffness of transcatheter aortic valve stent lattice structureFrontiers in Materials · 2026
- Hybrid Machine Learning Framework for Predicting the Biomechanical Performance of FDM-Manufactured PEEK Bone PlatesACS Applied Polymer Materials · 2026