Low PaO2 with normal saturation: beyond leukocyte-mediated hypoxemia.
Gerald S Zavorsky, Kaila A Labrador
Department of Physiology and Membrane Biology, University of California, Davis, Davis, CA, USA. · UC Davis School of Medicine, Sacramento, CA, USA.
Key points
From the paper's conclusion- Apparent spurious hypoxemia was more often explained by temperature reporting and fetal hemoglobin than oxygen metabolism by leukocytes; the leukocytosis signal could not be separated from neonatal physiology. Laboratories should identify the PaO2 reporting temperature, and clinicians should consider fetal-hemoglobin physiology before invoking leukocyte-mediated hypoxemia in neonates.
Abstract
OBJECTIVES: Spurious hypoxemia - a low PaO2 with preserved, directly measured oxyhemoglobin saturation (sO2) - is traditionally attributed to extreme leukocytosis or thrombocytosis ("leukocyte larceny"). We assessed how often it instead reflects PaO2 temperature reporting or neonatal fetal-hemoglobin physiology. METHODS: We retrospectively analyzed 7,473 arterial blood-gas specimens from 2,647 patients (September 2020-January 2026) with co-oximetry-derived sO2, complete blood count, and metabolic panel data; regression analyses used the 7,431 specimens reported within 80 min of collection. Spurious hypoxemia was defined as PaO2<60 torr (8.0 kPa) referenced to 37 °C at measured pH, with sO2≥92 %. Firth logistic regression, Kaplan-Meier analysis, and receiver-operating-characteristic curves evaluated temperature correction, neonatal status, and extreme leukocytosis (≥50 × 109/L) or thrombocytosis (≥500 × 109/L). RESULTS: Spurious hypoxemia affected 74 specimens (1.0 %). Among hypothermic specimens, the apparent rate fell from 3.5 % with PaO2 reported at patient temperature to 0.9 % when referenced to 37 °C. Rates were higher in normothermic infants than adults (5.4 vs. 0.3 %), consistent with fetal hemoglobin. Extreme leukocytosis was associated with the outcome (adjusted odds ratio 20.2; 95 % confidence interval 5.6-60.9), but all four events occurred in neonates. Longer collection-to-reporting time was modestly associated (odds ratio 1.45 per 10 min), mainly in neonates. No non-neonatal specimen with a white-cell count ≥30 × 109/L met the outcome (0/139), and extreme thrombocytosis showed no association (0/126). CONCLUSIONS: Apparent spurious hypoxemia was more often explained by temperature reporting and fetal hemoglobin than oxygen metabolism by leukocytes; the leukocytosis signal could not be separated from neonatal physiology. Laboratories should identify the PaO2 reporting temperature, and clinicians should consider fetal-hemoglobin physiology before invoking leukocyte-mediated hypoxemia in neonates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Occult hypoxemia in the ICU: Clinical risk factors, mortality and implications for nursing practice.Intensive & critical care nursing · 2026
- Quantifying the effects of hemoglobin saturation on plasma strong ion difference during blood oxygenation and decarboxylation.Physiological reports · 2026
- Pulse Oximetry and Arterial Blood Gas Agreement in an Outpatient Black Lung Clinic: Implications for Clinical Assessment and Decision Making.Journal of primary care & community health · 2026
- The occult hypoperfusion index: a bedside formula to identify undetected critical illnessBMC Medicine · 2026
- Hemolysis in neonatal whole-blood gas testing: prevalence and association with potassium.European journal of pediatrics · 2026
- Accuracy of pulse oximetry to determine severe hypoxemia in COPD patients: a cross-sectional study.Clinics (Sao Paulo, Brazil) · 2026