Clinics (Sao Paulo, Brazil)

Accuracy of pulse oximetry to determine severe hypoxemia in COPD patients: a cross-sectional study.

Luis Maurício Batalin Júnior, Jonathas William de Morais, Maércio Souza Cícero Dos Santos, Luís Fernando Pereira Brizola, Matheus Augusto Callegari, Danilo Augusto Ferrari Dias, Flávio Vinicius Fagundes Xavier, Estefânia Aparecida Thomé Franco,

Faculdade de Medicina de Botucatu (FMB), Universidade Estadual Paulista (UNESP), Botucatu Campus, Botucatu, SP, Brazil. · Hospital das Clínicas da Faculdade de Medicina de Botucatu (HCFMB), Universidade Estadual Paulista (UNESP), Botucatu Campus, Botucatu, SP, Brazil.

Observational · n=176

Key points

From the paper's conclusion
  • Pulse oximetry demonstrated excellent diagnostic accuracy for detecting severe hypoxemia in COPD outpatients. An SpO2 cutoff of ≤89% provided optimal sensitivity and specificity under standardized conditions.

Abstract

BACKGROUND: In moderate hypoxemia, Pulse Oximetry (SpO2) may indicate values above 90%, potentially underestimating severity in patients with COPD. This leads to the question of whether a similar discrepancy occurs in cases of severe hypoxemia. This study aimed to evaluate the diagnostic accuracy of SpO2 for identifying severe resting hypoxemia defined by PaO2 ≤55 mmHg and to determine a clinically applicable SpO2 cutoff for screening patients with COPD undergoing evaluation for LTOT. METHODS: Data were collected from medical records of patients attending a Long-Term Oxygen Therapy (LTOT) outpatient clinic. Severe hypoxemia was defined as PaO2 ≤55 mmHg. Agreement between SpO2 and co-oximetry (SaO2) was assessed following Bland and Altman recommendations. Receiver Operating Characteristic (ROC) curve analysis was performed using a PaO2 ≤ 55 mmHg cutoff to evaluate the accuracy of SpO2. RESULTS: Between January 2022 and December 2025, 176 patients were included (65% female, mean age: 71-years [SD = 9] and PaO2: 57.4 mmHg [SD = 10.8]). Bland-Altman analysis showed a mean bias of -0.43% (95% CI: -0.76 to -0.10) between SaO2 and SpO2, with 95% limits of agreement ranging from -4.77% to 3.90%. ROC curve analysis demonstrated excellent diagnostic performance of SpO2 for detecting severe hypoxemia, with an area under the curve of 0.939. The optimal statistical cutoff was 89.5%, corresponding to a clinically applicable threshold of SpO₂ ≤ 89%, and yielded a sensitivity of 88.5%, specificity of 87.8%, positive predictive value of 85.2%, and negative predictive value of 90.5%. CONCLUSIONS: Pulse oximetry demonstrated excellent diagnostic accuracy for detecting severe hypoxemia in COPD outpatients. An SpO2 cutoff of ≤89% provided optimal sensitivity and specificity under standardized conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers