Diagnostic accuracy of dried blood spot samples for hepatitis B diagnosis: a systematic review and meta-analysis.
Songhe Wang, Xitong Yao, Xinyu Zhang, Jiaoqiang Chen, Pin Han, Wei Bai
College of Basic Medical Sciences, Jilin University, Changchun, Jilin, P.R. China. · School of Public Health, Jilin University, Changchun, Jilin, P.R. China.
Key points
From the paper's conclusion- DBS-based HBsAg testing showed high diagnostic accuracy, supporting its use in community screening, primary care, and resource-limited settings.
Abstract
INTRODUCTION: Hepatitis B virus (HBV) infection remains a major global public health problem. Dried blood spot (DBS) sampling is simple to collect, stable during transport, and easy to store, and may therefore provide an alternative sampling strategy for decentralized HBV testing. CONTENT: PubMed, Web of Science, MEDLINE, and Cochrane were searched for English-language studies published up to August 19, 2025. Eligible studies used DBS as the index test and venous blood, serum, or plasma testing as the reference standard. SUMMARY: Forty-four studies were included, yielding 61 datasets: 36 for HBsAg, 11 for anti-HBc, and 14 for HBV DNA. Based on the bivariate random-effects model, the pooled sensitivity and specificity of DBS-based HBsAg testing were 0.943 (95 % CI, 0.916-0.962) and 0.988 (95 % CI, 0.980-0.993), respectively, with a pooled DOR of 1,995.07 (95 % CI, 834.68-4,768.66). The pooled sensitivity and specificity were 0.836 (95 % CI, 0.737-0.902) and 0.973 (95 % CI, 0.937-0.989) for DBS-based anti-HBc testing, and 0.869 (95 % CI, 0.787-0.922) and 0.963 (95 % CI, 0.932-0.980) for DBS-based HBV DNA testing, respectively. Subgroup analyses showed that specificity remained relatively stable across most subgroups. Leave-one-out sensitivity analyses showed no directional change in the overall results after omitting individual studies. OUTLOOK: DBS-based HBsAg testing showed high diagnostic accuracy, supporting its use in community screening, primary care, and resource-limited settings. DBS-based anti-HBc and HBV DNA testing also showed high specificity, but their sensitivity was relatively lower. Further standardization of sample volume, filter paper type, elution procedures, storage conditions, and positivity thresholds is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility, Accuracy, and Acceptability of Self-Collected Dried Blood Spots for Hepatitis C Virus, Hepatitis B Virus, and SARS-CoV-2 Testing.Open forum infectious diseases · 2026
- Use of Dried Blood Spots for Identifying Hepatitis E Infections in an Outbreak Setting.Journal of medical virology · 2026
- B-042 Performance evaluation of Atellica IM infectious disease assays with dried blood spot sampleClinical Chemistry · 2026
- Diagnostic performance, biological monitoring and care cascade of viral hepatitis in sub-Saharan Africa: a systematic review.Diagnostic microbiology and infectious disease · 2026
- Diagnostic Performance of Rapid Test Cassette Compared to Enzyme-Linked Immunosorbent Assay in the Screening of Anti-HBs in Sokoto, NigeriaInternational Journal of Health Sciences and Research · 2026
- B-163 Clinical Evaluation of the Newly Approved Access HBsAg assay for Enhanced Detection, Workflow Efficiency, and Analytical Integrity in the United StatesClinical Chemistry · 2026