Clinical chemistry and laboratory medicine

Model 1b analytical performance specifications - report on the Prague 2025 workshop.

Andrea R Horvath, Sverre Sandberg, Marc H M Thelen, Mauro Panteghini, Hikmet Can Çubukçu, Emmi Rotgers, Eric Kilpatrick, Katy J L Bell,

Department of Chemical Pathology, New South Wales Health Pathology, Prince of Wales Hospital, Level 4 Campus Centre, Randwick, Sydney, NSW, Australia. · Norwegian Organization for Quality Improvement of Laboratory Examinations (NOKLUS), Haraldsplass Deaconess Hospital, Bergen, Norway.

Key points

From the paper's conclusion
  • This report presents the expert presentations from the 2025 workshop, which exclusively focused on APS based on Model 1b.

Abstract

The main purpose of establishing APS is to ensure that test performance aligns with their specific clinical goals. Analytical performance specifications serve multiple functions: as acceptance criteria to verify that in vitro diagnostic medical devices (IVD MD) meet regulatory and quality standards before market release; for external quality assurance assessments; for quality control, monitoring reagent lot-to-lot variability, and allowing preanalytical variation assessments in labs; and for guiding purchasing decisions by healthcare providers, reimbursement agencies, and both public and private insurers. Over the years, various systems and projects have been established to evaluate the current state of the art (Model 3) of IVD MD through external quality assurance (EQA). Different national and international EQA providers often use distinct acceptance criteria tailored to their organisational goals and local healthcare settings. Model 2, which relies on biological variation data, has been effectively supported by the European Federation of Clinical Chemistry and Laboratory Medicine's database and its interactive tools for calculating APS (www.biologicalvariation.eu). Nonetheless, debates continue about optimal APS setting methods and the most suitable models for different measurands and scenarios. To explore these issues further, workshops were held in Prague in 2023 and 2025. This report presents the expert presentations from the 2025 workshop, which exclusively focused on APS based on Model 1b.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Model 1b analytical performance specifications - report on the Prague 2025 workshop — Science Skim