Key points
From the paper's conclusion- The 2025 biennial members and stakeholders' workshop focused on the expectations and benefits of harmonized results among medical laboratories, as well as the challenges associated with achieving this goal.
Abstract
diagnostic (IVD) medical devices. The 2025 biennial members and stakeholders' workshop focused on the expectations and benefits of harmonized results among medical laboratories, as well as the challenges associated with achieving this goal. Harmonization of results from end-user IVD measurement procedures (IVD-MPs) can be achieved by applying the principles of metrological traceability; however, there are several historical examples of standardization efforts that did not achieve the required level of harmonization. The reasons for these failures can be found in various elements of the calibration hierarchy including: a) an unclear definition of the measurand, b) differences in selectivity of the IVD-MPs, c) issues with the commutability characteristics of secondary certified reference materials (CRM), d) inconsistencies in handling of CRMs to prepare calibrators, and e) lack of adoption and implementation by the IVD manufacturers. The lack of harmonized results can lead to confusion, treatment delays, errors in medical decisions, and increased healthcare costs. There are still assays in common use that lack metrological traceability because they lack CRMs, reference method procedures (RMPs), and/or reference method services (RMSs). Producing and maintaining reference measurement system components is complex and expensive. There are multiple regulatory frameworks and requirements that IVD manufacturers must meet worldwide. There is a vital role for External Quality Assessment (EQA) providers to assess the agreement status of results across different IVD-MPs and identify any changes in their equivalence. However, EQA materials must be commutable with clinical samples for each of the examined IVD-MDs for results to reflect the status of harmonization of clinical sample results. The future will need leadership and cooperation between bodies such as JCTLM, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), and IVD manufacturers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Filling the gaps in high-priority reference materials for implementing metrological traceability in laboratory medicine.Clinical chemistry and laboratory medicine · 2026
- Extending external quality assessment to cover what is missing from the quality indicators we currently measure?Clinical chemistry and laboratory medicine · 2026
- A Comprehensive Analysis of Metrological Traceability Tools for Urine Albumin MeasurementsClinical Chemistry · 2026
- Evaluating feasibility of ferritin assay harmonisation with commutable proof-of-concept reference materials and EQA-based monitoring.Clinical chemistry and laboratory medicine · 2026
- Analysis of Quality Normative Requirements: Contributions to the Alignment and Standardization of Standards Applied in Health Laboratories.Biotech (Basel (Switzerland)) · 2026
- Beyond proficiency testing: Leveraging commutable External Quality Assessment data to harmonize tumor markers and refine medical decision points.Tumour biology : the journal of the International Society for Oncodevelopmental Biology and Medicine · 2026