Pumpless extracorporeal lung assist device in the management of idiopathic pulmonary arterial hypertension - implantation, weaning and explantation in a bridge-to-decision concept.
Fabian A Kari, Jürgen Hörer, Christian Schneider, Nikolaus Haas, Joseph Pattathu, A Maskos, Sebastian G Michel
Division for Pediatric and Congenital Heart Surgery, LMU University Hospital, Munich, Germany · Comprehensive Pneumology Center Munich, German Center for Lung Research (DZL), Germany
Key points
From the paper's conclusion- A low-resistance oxygenator (QUADROX, Maquet) is used for paracorporeal lung assist.
Abstract
Via a primary sternotomy approach, cardiopulmonary bypass is established in a standard fashion including a separate vent in the main pulmonary artery. The outlet cannula, an angled Berlin Heart EXCOR cannula, is implanted into the body of the small, underfilled, left atrium using felt-supported single sutures. The inlet cannula, a 12 mm Berlin Heart graft adapter cannula connected to a 12 mm Terumo prosthesis and draining deoxygenated blood from the main pulmonary artery, is tunnelled through the epigastric skin and subsequently anastomosed with the main pulmonary artery. A low-resistance oxygenator (QUADROX, Maquet) is used for paracorporeal lung assist.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aorto-Pulmonary Shunt Creation in Congenital Heart Disease: Different Indications, Various Modifications, but Common Technical Challenges.Pediatric cardiology · 2026
- Successful bridge to heart transplantation in a pediatric patient with biventricular heart failure associated with Barth syndrome: a case report.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026
- Refractory cardiac arrest during epidural anesthesia for caesarean section in a patient with supra-systemic pulmonary hypertension rescued by VA ECMOSaudi Journal of Anaesthesia · 2026
- Novel Transvenous Approach for Implantable Cardioverter-Defibrillator Implantation in a Patient With Fontan Circulation: Trans-Left Pulmonary Artery-Left Atrium.JACC. Case reports · 2026
- Percutaneous sheathless subclavian intra-aortic balloon pump implantation as a bridge to heart transplantation: a feasibility study.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026
- Berlin heart EXCOR® implantation for Fontan failure in right-sided heterotaxy with ventricular septal protuberance: autopsy case report.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026