Association of Coronary Vessel Tapering with Postprocedural Residual Diameter Stenosis After Drug-Coated Balloon Angioplasty: A Retrospective Registry Study.
Sezgin Uzunoğlan, Hasan Burak İşleyen, Behice Hande Şişman Uzunoğlan, Oğuzhan Abanoz, Esra Danışman, Mahmut Uluganyan
Department of Cardiology, Kırklareli Training and Research Hospital, Kırklareli, Türkiye. · Department of Cardiology, Faculty of Medicine, Nişantaşı University, İstanbul, Türkiye ; Department of Cardiology, Faculty of Medicine, Bezmialem Vakıf University, İstanbul, Türkiye.
Key points
From the paper's conclusion- The adjusted primary estimate did not demonstrate a statistically discernible association between coronary tapering and post-DCB percentage diameter stenosis, although small effects in either direction could not be excluded. Secondary absolute-lumen findings require prospective core-laboratory validation and do not support empirical balloon oversizing.
Abstract
OBJECTIVE: To evaluate whether proximal-to-distal coronary tapering is associated with registry-designated post-drug-coated balloon (DCB) percentage diameter stenosis. METHODS: This retrospective single-center registry analysis included 1 designated index-lesion row per patient. Eligibility required observed post-DCB diameter stenosis and at least 1 observed preprocedure proximal or distal reference-vessel diameter (RVD). Tapering was defined from the phase 0 preprocedure RVDs as (proximal RVD-distal RVD)/mean RVD. The adjusted linear model used heteroskedasticity-consistent standard errors and 50 chained-equation imputations for missing exposure/covariate data; the outcome was not imputed. RESULTS: Of 509 source records, 354 were eligible. Per 0.10 greater tapering, the adjusted difference in post-DCB diameter stenosis was 0.32 percentage points (95% CI, -0.10 to 0.74; P = .132). Estimates were similar across complete-case, restriction, inverse-probability-weighted, influence, and median-regression analyses. Observed-only secondary analyses showed lower post-DCB minimal lumen diameter (-0.033 mm; 95% CI, -0.049 to -0.018; P < .001) and normalized acute gain (-0.014; 95% CI, -0.023 to -0.005; P = .002). CONCLUSION: The adjusted primary estimate did not demonstrate a statistically discernible association between coronary tapering and post-DCB percentage diameter stenosis, although small effects in either direction could not be excluded. Secondary absolute-lumen findings require prospective core-laboratory validation and do not support empirical balloon oversizing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acute and Late Angiographic Lumen Assessment of the Coronary Artery Diameter After Drug Coated Balloon Angioplasty.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- The application of drug-coated balloon to in situ short and long lesions of large coronary artery vessels.Frontiers in cardiovascular medicine · 2026
- Safety and effectiveness of drug-coated balloon angioplasty in de novo coronary lesions: 6-month outcomes from a multicenter registryEuropean Heart Journal · 2026
- Evaluating drug-coated balloon versus drug-eluting stent for the treatment of small coronary artery disease: a meta-analysis and systematic review.Frontiers in cardiovascular medicine · 2026
- Outcomes of Drug-Coated Balloon Versus Drug-Eluting Stent for the Treatment of Large De Novo Coronary Lesions.Reviews in cardiovascular medicine · 2026
- Calcification Remains Detrimental Despite Post-Procedural Lumen Expansion After Drug-Coated Balloon Treatment of Femoropopliteal Artery Lesions: Results From a Multicenter Retrospective Registry.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026