Bone Morphogenetic Protein-10 as a Predictor of Atrial Fibrillation Recurrence After Catheter Ablation: A Systematic Review and Meta-Analysis.
Naveed Mohsin, Martin Eugene Matsumura, Tariq Ahmad, Kaif Ul Sahar
Department of Internal Medicine, Geisinger Wyoming Valley Hospital, Wilkes-Barre, PA 18711, USA. · Department of Cardiology, Geisinger Wyoming Valley Hospital, Wilkes-Barre, PA 18711, USA.
Key points
From the paper's conclusion- Elevated BMP10 levels are correlated with higher risk of AF recurrence following catheter ablation. Although the results are consistent across analyses, they should be interpreted with caution due to the small number of studies and methodological heterogeneity. BMP10 needs to be confirmed as a clinically applicable biomarker by larger prospective studies.
Abstract
BACKGROUND: Biomarkers of atrial cardiomyopathy may improve the prediction of recurrence of atrial fibrillation (AF) after catheter ablation. Bone morphogenetic protein-10 (BMP10) is an atrial-specific cardiomyocyte protein and a potential biomarker, but evidence is limited and not comprehensively synthesized. METHODS: We performed a systematic review and meta-analysis of prospective cohort studies to evaluate the association between circulating BMP10 concentrations with AF recurrence after catheter ablation. Pooled hazard ratios (HRs) with corresponding 95% confidence intervals (CIs) were computed using a random-effects model. The primary analysis used unadjusted HRs per continuous BMP10 levels from all included studies. Secondary analyses were conducted based on the adjusted HRs of studies with continuous BMP10 and all studies, including one study that reported adjusted HRs based on quartiles. RESULTS: Three studies were included. In the primary analysis without adjustment (n = 3), increased levels of BMP10 were significantly associated with recurrence of AF (pooled HR 1.53, 95% CI 1.13-2.07; P = 0.006), with moderate-to-high heterogeneity (I2 = 69%). The association was attenuated and non-significant in the adjusted analysis of two studies with continuous BMP10 (HR 1.46, 95% CI 0.94-2.25; I2 = 59%). However, after the inclusion of a third study with adjusted quartile-based HR, the statistical significance was re-demonstrated (HR 1.33, 95% CI 1.16-1.53; P < 0.001) with low heterogeneity (I2 = 20%). CONCLUSION: Elevated BMP10 levels are correlated with higher risk of AF recurrence following catheter ablation. Although the results are consistent across analyses, they should be interpreted with caution due to the small number of studies and methodological heterogeneity. BMP10 needs to be confirmed as a clinically applicable biomarker by larger prospective studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bone morphogenetic protein 10 and one-year outcomes after open revascularisation in symptomatic peripheral arterial disease or carotid stenosis.BMC cardiovascular disorders · 2026
- Bone morphogenetic protein 10, a novel marker of atrial stress, is associated with incident heart failure in the general populationEuropean Heart Journal · 2026
- Baseline circulating thrombospondin-1 is associated with recurrence after catheter ablation in paroxysmal atrial fibrillation: A retrospective cohort study.International journal of cardiology · 2026
- Dynamic BMP10 Release Reflects Atrial Fibrillation Burden in Human Atrial Engineered Heart TissuebioRxiv · 2026
- Plasma level of extracellular matrix biomarkers is associated with the recurrence of atrial fibrillationEuropean Heart Journal · 2026
- Changes in circulating biomarkers in symptomatic atrial fibrillation from before to one day after catheter ablationScientific Reports · 2026