Fiducial marker-guided microwave ablation of liver tumors occult on conventional ablation-guidance imaging: A prospective single-center technical feasibility study.
Soumil Singhal, Gaurav Meel, Vinamrita Patni, Malik Faizan Abass, Sudhir Yadav, Anubhav Khandelwal, Sanjay Saran Baijal
Department of Interventional Radiology, Medanta: The Medicity, Gurugram, India.
Key points
From the paper's conclusion- Percutaneous gold fiducial tagging with vector-guided MWA is a feasible and reproducible strategy for ablating liver tumors that are occult on conventional planning modalities, achieving high targeting reproducibility and early local control in a selected cohort.
Abstract
BACKGROUNDS/AIMS: Some liver tumors are visible on dynamic magnetic resonance imaging (MRI) yet remain occult on ultrasound (US), non-enhanced computed tomography (CT), US-CT/MRI fusion imaging, and contrast-enhanced US, which precludes image-guided ablation. We report a prospective single-center feasibility study of percutaneous gold fiducial tagging undertaken to enable microwave ablation (MWA) of such lesions. METHODS: Of 168 patients (204 lesions) referred for hepatic ablation between January 2024 and March 2025, 25 lesions in 20 patients were occult on all four modalities and were enrolled. A single gold fiducial was implanted under US guidance one day before ablation using MRI-derived anatomic landmarks. Post-placement imaging characterized the three-dimensional fiducial-to-lesion offset and thereby provided a calibrated targeting vector for MWA. Technical success was defined as complete lesion coverage with a ≥ 5 mm circumferential margin on post-procedure imaging. RESULTS: All 25 fiducials were placed without complications (median fiducial-to-lesion distance 8 mm, range 2-19). MWA was technically successful in 25 of 25 lesions (100%), and an independently confirmed ≥ 5 mm margin was achieved in every case. No procedure-related complications occurred and no local tumor progression was detected over a median follow-up of 21 months (range 12-30). CONCLUSIONS: Percutaneous gold fiducial tagging with vector-guided MWA is a feasible and reproducible strategy for ablating liver tumors that are occult on conventional planning modalities, achieving high targeting reproducibility and early local control in a selected cohort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cone-Beam CT Hepatic Arteriography-Guided Microwave Ablation of Ultrasound-Occult Liver Lesions.Journal of vascular and interventional radiology : JVIR · 2026
- Manufacturer-chart versus measured ablation volumes after microwave ablation of hepatocellular carcinoma in cirrhotic livers: a retrospective cohort studyCVIR Oncology · 2026
- MRI-guided microwave ablation of hepatic malignancies: 4-year institutional outcomes.PloS one · 2026
- Deep learning-based CNN method for fiducial marker detection in kilovoltage X-ray images for liver tumor motion monitoring.Medical physics · 2026
- Experience of Microwave Ablation of Liver Tumors in Special Sites Under Ultrasound Guidance: Review of the Literature With Image Illustration.Journal of clinical ultrasound : JCU · 2026
- Case Report: Delayed appearance of the ablation margin after CT-guided microwave ablation of a solid pulmonary nodule.Frontiers in medicine · 2026