From the paper's conclusion- Conclusions In this selected cohort of HCCs in cirrhotic livers, measured ablation volumes were frequently smaller than manufacturer-chart values.
Abstract
Objectives To assess agreement between manufacturer-chart volumes and immediate and 1-month measured ablation volumes (AV) after microwave ablation (MWA) of hepatocellular carcinoma (HCC) in a cohort of patients with cirrhosis. Materials and methods This single-center retrospective cohort included patients with cirrhosis and BCLC stage 0/A/B HCC who underwent MWA between November 28, 2022, and June 30, 2025. The database cutoff was March 31, 2026. Forty-three lesions in 29 patients were treated during 29 procedures under ultrasound or CT hepatic arteriography guidance. Immediate and 1-month measured volumes were compared with values recorded from the manufacturer’s in vivo liver chart. The primary difference was defined as measured minus predicted volume. Bland–Altman analyses included all 43 pairs and used a patient-level random-intercept model; a one-lesion-per-patient sensitivity analysis was also performed. Results Measured volume was smaller than predicted in 41/43 lesions (95.3%; 95% CI, 84.2%–99.4%). The cluster-adjusted mean bias was − 8.50 cm 3 (95% CI, − 10.28 to − 6.71), with limits of agreement from − 18.63 cm 3 (95% CI, − 20.93 to − 15.45) to 1.64 cm 3 (95% CI, − 0.99 to 3.78). The proportional-bias slope was 0.34 (95% CI, 0.02–0.65; p = 0.037), and residual dispersion increased with pair mean ( p = 0.010). The adjusted difference between subcapsular and perivascular lesions was 1.83 cm 3 (95% CI, − 1.98 to 5.65; p = 0.331). Conclusions In this selected cohort of HCCs in cirrhotic livers, measured ablation volumes were frequently smaller than manufacturer-chart values.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microwave Ablation Versus Radiofrequency Ablation for Hepatocellular Carcinoma: A Systematic Review and Meta-Analysis.Cureus · 2026
- Factors associated with treatment response to microwave ablation of benign thyroid nodules: a retrospective single-center study of nodule composition and vascularity.Frontiers in endocrinology · 2026
- Cone-Beam CT Hepatic Arteriography-Guided Microwave Ablation of Ultrasound-Occult Liver Lesions.Journal of vascular and interventional radiology : JVIR · 2026
- MRI-guided microwave ablation of hepatic malignancies: 4-year institutional outcomes.PloS one · 2026
- Results from the Pan-European CIEMAR study: Local Tumour Control After Microwave Ablation of Colorectal Liver Metastases and Exploratory Associations with Ablation Margins and Confirmation Software.Cardiovascular and interventional radiology · 2026
- Open Salvage Microwave Ablation for Refractory Diffuse Hepatic Oozing After Abandonment of Planned Hepatectomy for Large Hepatocellular Carcinoma.Journal of hepatocellular carcinoma · 2026