Relative humidity in intermittently conditioned energy-efficient homes: a preliminary hygrothermal assessment of indoor condensation and mould risk.

Liqun Guan, Mark Dewsbury, Hartwig Kuenzel, Louise Wallis

University of Tasmania, Launceston, Australia. · Fraunhofer Institute for Building Physics, Munich, Germany.

Computational

Key points

From the paper's conclusion
  • The findings reveal the limitations of continuous conditioning assumptions for moisture control design and underscore the problem of underestimating moisture risks in buildings.

Abstract

Rising global temperatures and increasing energy demand have led to more stringent energy efficiency requirements in buildings. While these measures reduce energy use, they may unintentionally increase the risk of indoor and interstitial moisture accumulation and mould growth. Highly insulated and airtight dwellings, combined with occupant-controlled ventilation and intermittent space conditioning without relative humidity regulation, can create environments conducive to mould, threatening indoor air quality, occupant health and building durability. In Australia, the 2022 National Construction Code mandates a minimum 7-star building envelope focused energy rating for new residential dwellings. Unlike international standards, Australian regulations include intermittent conditioning without specifying indoor relative humidity limits, potentially increasing moisture-related risks. This study examines the effects of intermittently conditioned indoor climate on interstitial moisture accumulation and mould growth in two of the most common low-rise timber-framed wall systems: clay masonry veneer and compressed fibre cement sheet cladding within temperate Australian climate zones. Ten-year transient hygrothermal simulations were conducted to quantify moisture and mould risks. Results show, without relative humidity control, indoor conditions frequently exceed the internationally recommended 70% relative humidity threshold, significantly increasing interstitial mould risk, particularly in bedrooms and open-plan living space. Comparisons with continuous conditioning, per the American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 160, indicate lower risks under continuous conditions. Mitigation strategies, including ventilated cavities and internal vapour control layer, were effective under continuous conditioning but exhibited inconsistent performance under conditions of unregulated relative humidity in intermittent conditioning. The findings reveal the limitations of continuous conditioning assumptions for moisture control design and underscore the problem of underestimating moisture risks in buildings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers