Refined anatomy-based fitting reduces interaural place mismatch and improves speech outcomes, with preliminary evidence for reduced listening effort.
Anja Kurz, Giovanna Castillo, Kristen Rak, Stephan Hackenberg, Alexander Möltner
Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Comprehensive Hearing Center, University of Würzburg, Würzburg, Germany. · MED-EL Headquarters, Innsbruck, Austria.
Key points
From the paper's conclusion- rfABF shows clinical potential to improve speech understanding and facilitate access to binaural cues in bilateral CI users with asymmetric electrode array insertions, with preliminary evidence for reduced listening effort.
Abstract
OBJECTIVE: This study proposes a refined approach to anatomy-based fitting (rfABF) that aims to reduce interaural place mismatch in bilateral cochlear implant (CI) users with asymmetric electrode array insertions between ears, a condition frequently associated with incomplete cochlear coverage. DESIGN: Prospective monocenter proof-of-concept study comparing rfABF with conventional clinically based fitting (CBF). ABF maps were prepared using two algorithmically derived methods: one scaling inter-electrode spectral spacing (zipped), and another transposing the ratio between clinical and tonotopic frequencies (transposed). These maps were then refined based on user feedback until a natural sound quality was achieved. Assessments consisted of speech perception in quiet and noise, sound localization, subjective sound quality ratings (HISQUI19), and listening effort assessed using pupillometry. STUDY SAMPLE: Nine experienced adult bilateral CI users with interaural asymmetry in electrode array insertion depth and/or electrode array type. RESULTS: Bilateral speech understanding improved significantly with rfABF in quiet (CBF: 77.5% ± 8.1%; rfABF: 83.1% ± 8.0%; p = 0.025) and in noise under both S0N0 (signal and noise from front) and S0Ncontra (signal from front, noise from contralateral ear) configurations. Interaural place-of-stimulation mismatch was substantially reduced from a mean of 33.8° ± 27.3° to 6.4° ± 4.2° with rfABF. Exploratory, descriptive pupillometry indicated reduced listening effort in a subset of participants, reflected by lower event-related pupil dilation (ERPD) amplitudes, particularly in cases where speech intelligibility was preserved or improved. CONCLUSIONS: rfABF shows clinical potential to improve speech understanding and facilitate access to binaural cues in bilateral CI users with asymmetric electrode array insertions, with preliminary evidence for reduced listening effort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Speech, spectral cue and harmony perception in cochlear implant recipients with anatomy-based fitting: a prospective, randomized, multicenter trialScientific Reports · 2026
- Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation StudyarXiv · 2026
- Effect of cochlear implant processing, interaural place mismatch, and spread of excitation on interaural coherence of speech signals and its implications on binaural fusion.Cochlear implants international · 2026
- The Effect of Between-Ear Speech Perception Asymmetry on Localization, Spoken Language, and Literacy for Adolescents With Cochlear Implants.Journal of speech, language, and hearing research : JSLHR · 2026
- Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEVarXiv · 2026
- Results for Adults with Asymmetric Hearing Loss Who Receive a Cochlear Implant.Audiology research · 2026